v
You
cannot
use
this
procedure
if
you
have
a
DS4100
or
DS4400
with
firmware
version
05.42.xx.xx
or
06.xx.xx.xx,
respectively.
In
addition,
you
do
not
need
to
go
though
this
procedure
if
you
have
a
DS4300
or
DS4500
controller
with
firmware
versions
05.41.5x.xx
or
06.xx.xx.xx
Preparing
for
the
upgrade
You
must
review
and
complete
all
of
the
steps
in
this
section
before
you
complete
the
upgrade
procedures.
Before
you
begin:
Ensure
that
you
have
the
latest
version
of
the
DS4000
Storage
Manager
installed
on
your
DS4000
management
station.
You
can
download
the
latest
version
from
the
following
IBM
DS4000
support
Web
site:
http://www-1.ibm.com/servers/storage/support/disk/
For
more
information
about
Storage
Manager,
see
the
appropriate
IBM
TotalStorage
DS4000
Storage
Manager
Installation
and
Support
Guide
for
your
host
operating
system.
Complete
the
following
steps
to
prepare
your
system
for
the
firmware
upgrade
procedures:
Backup
your
logical
drives
Complete
a
full
backup
of
all
logical
drives
that
are
defined
in
the
DS4000.
Stop
I/O
using
one
of
the
following
methods
Stop
all
I/O.
If
you
do
not
stop
I/O,
then
drives
might
be
marked
as
Failed
during
the
download.
This
can
cause
the
array
(or
arrays)
to
be
degraded
or
failed.
Use
one
of
the
following
methods
to
stop
I/O
from
the
host
server
(or
servers)
to
the
logical
drives.
The
methods
are
listed
in
order
from
the
most
desirable
to
the
least
desirable
option.
Note:
If
you
are
using
in-band
management
to
manage
the
DS4000
storage
subsystem,
you
cannot
use
method
or
method
1.
Shut
down
all
host
servers
that
have
logical
drives
mapped
to
them
(recommended
method).
This
method
might
not
be
feasible
if
you
are
using
the
host
server
as
the
DS4000
management
station.
In
that
case,
method
is
the
best
choice.
2.
Stop
all
programs,
services
or
processes
in
the
host
servers
that
access
the
logical
drives.
Make
sure
that
you
stop
any
running
background
programs,
services
or
processes
that
write
data
to
the
logical
drives.
(For
example,
Microsoft
MSCS
is
a
background
program
that
periodically
writes
to
the
Quorum
disk.)
If
you
use
this
method,
also
use
method
to
flush
I/O
from
the
server
cache
to
disks.
3.
Unmount
the
file
systems
to
flush
I/O
from
the
server
cache
to
disks.
Note:
In
a
Microsoft
Windows
environment,
remove
the
drive
letter
or
the
mount
points
of
the
mapped
LUNs,
instead
of
unmounting
the
file
systems.
4.
Remove
the
logical
drive-to-host
mappings,
using
the
DS4000
Storage
Manager
client.
Appendix
A.
Upgrading
R1-level
firmware
(DS4300
and
DS4500
only)
109
Содержание TotalStorage EXP100
Страница 2: ......
Страница 10: ...viii IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 12: ...x IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 18: ...xvi IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 132: ...106 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 148: ...122 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 160: ...134 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 162: ...136 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 164: ...138 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 180: ...154 IBM TotalStorage DS4000 EXP100 Storage Expansion Enclosure Installation User s and Maintenance Guide ...
Страница 187: ......
Страница 188: ... Part Number 39M5947 Printed in USA GC26 7694 01 1P P N 39M5947 ...