Table 56. Symptom-to-FRU index (continued)
Problem
indicator
Component
Possible cause
Possible solutions
The DS Storage
Manager client
Enterprise
Management
window sees
each storage
subsystem
controller as an
independent
storage
subsystem or a
partially
managed device.
Controller
If this condition occurs after
you have replaced a
controller, the controller
firmware for the replacement
controller probably failed to
synchronize with the
firmware on the existing
controller.
To recover, perform the following steps:
1. Remove and reinsert the controller blade.
2. Wait 5 minutes.
3. Delete the controller entry with the incorrect
firmware version from the DS Storage
Manager Enterprise Management window.
4. Add the controller back to the DS Storage
Manager Enterprise Management window
using the
Add Device
menu option in the
Enterprise Management window.
5. If the DS Storage Manager client Enterprise
Management window still shows each storage
subsystem controller as an independent
storage subsystem or a partially managed
device, contact IBM support for instructions on
how to force firmware synchronization in the
replacement controller.
The DS5100 and DS5300
has been powered on
without a connection to at
least one storage expansion
enclosure populated with at
least two drives.
If this is the case, power off the storage
subsystem and connect at least one storage
expansion enclosure populated with at least two
drives.
The attached storage
expansion enclosures and/or
drives in the attached
storage expansion
enclosures are not certified
or not supported by the
storage subsystem.
The storage subsystem will not recognize non-IBM
storage expansion enclosures and drive models. If
you are positive that storage expansion
enclosures and drives are of IBM models, obtain
the Subsystem Profile and call IBM support.
Random errors
Subsystem
Midplane has failed
Contact IBM Support.
Note:
If you cannot find the problem in the Symptom-to-FRU index, test the entire
system.
Parts list
Figure 126 on page 209 and the following table provide a parts list for the DS5100
and DS5300.
208
IBM System Storage DS5100 and DS5300 Storage Subsystem: Installation, User’s, and Maintenance Guide
Содержание TotalStorage DS5100
Страница 1: ...IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 2: ......
Страница 3: ...IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 12: ...x IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 18: ...xvi IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 22: ...xx IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 64: ...32 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 78: ...46 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 158: ...126 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 232: ...200 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 260: ...228 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 268: ...236 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 288: ...256 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 294: ...262 IBM System Storage DS5100 and DS5300 Storage Subsystem Installation User s and Maintenance Guide ...
Страница 295: ......
Страница 296: ... Part Number 59Y7242 Printed in USA 1P P N 59Y7242 ...