The
Service
Action
Allowed
status
LED
automatically
turns
on
or
off
as
conditions
change.
Wait
at
least
two
minutes
after
you
replace
each
component
for
the
controller
to
recognize
the
new
component
and
update
the
LED
status.
In
most
cases
when
a
single
component
fails,
the
Service
Action
Allowed
status
LED
turns
on
steadily
when
the
Needs
Attention
status
LED
is
turned
on
for
the
component.
Replacing
a
controller
Attention:
Before
you
replace
a
controller,
verify
the
following:
v
The
replacement
controller
part
number
matches
the
part
number
of
the
controller
to
be
replaced.
To
provide
full
functionality,
the
two
controllers
should
have
the
same
cache
memory
capacity
and
FRU
part
number.
Inserting
a
non-compatible
controller
causes
the
controller
to
be
placed
in
a
lockout
state
by
the
other
controller
in
the
DS4200
Express
chassis.
Note:
The
DS4200
Express
Storage
Subsystem
controller
FRU
is
not
compatible
with
the
DS4700
Storage
Subsystem
controller
FRUs.
v
Both
power
supply
and
fan
units
must
be
connected
and
powered
on
with
no
Needs
Attention
LEDs
lit.
Ensure
that
the
Power
LEDs
on
each
of
the
power
supply
and
fan
units
are
lit.
If
either
of
the
power
supply
and
fan
units
is
not
optimal,
it
is
recommended
that
you
replace
that
component
before
you
proceed
with
the
controller
replacement
procedure.
v
If
you
are
replacing
an
optimal
controller,
first
make
sure
that
the
other
controller
is
optimal
and
that
the
fibre
channel
path
from
the
hosts
to
the
other
controller
is
also
optimal.
Use
the
following
procedure
to
replace
a
controller
in
an
DS4200
Express
Storage
Subsystem.
Each
controller
has
a
unique
hardware
Ethernet
address,
which
is
printed
on
a
label
on
the
front.
1.
Use
the
DS4000
Storage
Manager
client
software
to
a
storage
subsystem
profile.
Move
logical
drive
ownership
to
the
other
controller.
If
the
controller
you
are
replacing
has
failed
but
is
still
operating,
move
the
failed
controller
to
an
Offline
state.
Attention:
Never
remove
a
controller
unless
the
Service
Action
Allowed
status
LED
is
turned
on.
Doing
so
can
result
in
a
potential
loss
of
data.
2.
Locate
the
failed
controller
by
checking
the
Needs
Attention
status
LEDs
on
the
controllers
in
the
storage
subsystem.
3.
Is
the
Service
Action
Allowed
status
LED
turned
on?
v
Yes
–
Go
to
step
v
No
–
Another
component
might
require
attention
before
you
can
remove
the
controller.
Use
the
Recovery
Guru
function
in
the
DS4200
Express
Subsystem
Management
window
to
identify
and
correct
any
additional
failures.
If
there
are
none,
proceed
with
step
to
replace
the
controller.
Electrostatic
discharge
can
damage
sensitive
components.
Touching
the
storage
subsystem
or
its
components
without
using
a
proper
ground
might
damage
the
equipment.
To
avoid
damage,
use
proper
antistatic
protection
while
handling
any
components.
4.
Put
on
antistatic
protection.
5.
Unpack
the
new
controller.
Save
all
packing
materials
in
the
event
you
need
to
return
the
new
controller.
106
IBM
System
Storage
DS4200
Express
Storage
Subsystem:
Installation,
User’s
and
Maintenance
Guide
Содержание TotalStorage DS4200
Страница 2: ......
Страница 12: ...x IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 18: ...xvi IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 26: ...xxiv IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 48: ...22 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 68: ...42 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 130: ...104 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 160: ...134 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 168: ...142 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 178: ...152 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 192: ...166 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 194: ...168 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 196: ...170 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 212: ...186 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 218: ...192 IBM System Storage DS4200 Express Storage Subsystem Installation User s and Maintenance Guide...
Страница 221: ......
Страница 222: ...Part Number 41Y0718 Printed in USA GC27 2048 00 1P P N 41Y0718...