DNS
servers
Enter
the
IP
addresses
of
up
to
three
systems
that
will
act
as
DNS
servers.
Enter
no
to
clear
the
list
of
DNS
servers.
dhcp
Enter
yes
if
a
DHCP
server
will
be
used
to
discover
the
system
network
values.
Enter
no
if
a
DHCP
server
will
not
be
used.
If
you
enter
yes
,
the
wizard
takes
you
to
the
finish
parameter.
If
you
enter
no
,
the
wizard
continues
to
prompt
you
for
information
about
the
main
Ethernet
interface
of
the
system.
IP
address
Enter
the
IP
address,
in
x.x.x.x
format.
You
can
also
define
the
netmask
by
typing
its
width
after
the
IP
address.
Note:
For
the
DS300
storage
subsystem,
the
management
interface
must
be
in
a
separate
network
segment
from
your
iSCSI
ports.
netmask
Define
the
size
of
the
netmask.
Any
of
the
common
formats
are
accepted.
Note:
If
you
entered
the
netmask
as
part
of
the
IP
address
in
the
previous
prompt,
this
parameter
is
skipped.
broadcast
address
Enter
the
address
to
be
used
for
broadcasts.
Any
of
the
common
formats
are
accepted.
peer
IP
address
Enter
the
IP
address
for
the
peer
controller,
in
x.x.x
format.
Note:
For
the
DS300
storage
subsystem,
the
management
interface
must
be
in
a
separate
network
segment
from
your
iSCSI
ports.
peer
netmask
Define
the
size
of
the
netmask
for
the
peer
controller.
Any
of
the
common
formats
are
accepted.
peer
broadcast
address
Enter
the
address
to
use
by
the
peer
controller
for
broadcasts.
Any
of
the
common
formats
are
accepted.
finish
Enter
yes
to
apply
the
values
that
you
have
entered,
or
enter
no
to
return
to
the
first
parameter
and
change
the
values
that
you
have
entered.
Note:
If
you
changed
the
management
IP
address
in
step
4
on
page
2,
you
must
open
a
Telnet
session
to
the
new
IP
address.
Installing
IBM
ServeRAID
Manager
and
adding
a
ServeRAID
agent
To
install
the
IBM
ServeRAID
Manager
program
and
add
a
ServeRAID
agent
for
the
storage
subsystem,
complete
the
following
steps:
1.
Install
the
ServeRAID
Manager
program
on
the
management
station,
using
the
ServeRAID
Application
CD
that
comes
with
the
DS300
or
DS400
storage
subsystem
(see
the
IBM
TotalStorage
DS300
and
DS400
Software
Installation
Guide
for
help
with
installing
ServeRAID
Manager).
2.
Start
the
ServeRAID
Manager
program;
then,
complete
the
following
steps
to
add
a
management
station
object
and
a
ServeRAID
agent
for
the
storage
subsystem:
a.
To
add
a
management
station
object,
right-click
Networked
Storage
in
the
ServeRAID
Manager
interface;
then,
select
Add
Management
Station
(see
“Adding
a
remote
system
object”
in
the
ServeRAID
Manager
online
help
for
more
information
about
adding
a
management
station).
3