Single
Library
Manager
Configuration:
For
a
single
Library
Manager
configuration,
perform
the
following
steps:
1.
Wait
for
the
Library
Manager
to
be
re-initialized
and
enter
the
Auto
mode,
Online
state.
This
may
take
up
to
20
minutes.
2.
If
the
failure
occurred
while
inserting
cartridges
into
the
high-capacity
I/O
facility,
do
not
remove
the
cartridges.
Leave
the
cartridges
in
place,
and
the
operation
restarts
automatically.
Cartridges
inserted
in
the
convenience
I/O
station
that
remain
in
the
station
must
be
removed
from
the
station,
then
reinserted
after
the
Library
Manager
re-initializes.
3.
If
the
Library
Manager
reflects
the
Auto
mode,
Online
state,
it
has
recovered.
Call
your
service
representative
for
a
recoverable
Library
Manager
error.
Continue
with
or
4.
If
the
Library
Manager
does
not
display
the
Auto
mode,
Online
state
and
more
than
30
minutes
have
elapsed
since
the
re-initialization
started,
call
your
service
representative
for
a
unrecoverable
Library
Manager
error.
5.
When
the
repair
action
is
completed
and
the
library
is
available
to
be
varied
online,
continue
with
Dual
Library
Manager
Configuration:
For
a
dual
Library
Manager
configuration,
perform
the
following
steps:
1.
Wait
until
the
switchover
completes
and
the
standby
Library
Manager
has
become
the
active
Library
Manager.
The
switchover
takes
approximately
ten
minutes
(see
2.
Call
your
service
representative
to
repair
the
failed
Library
Manager.
The
failed
Library
Manager
may
recover
from
the
failure
and
become
available
as
the
standby
Library
Manager
after
the
database
is
synchronized.
3.
If
the
failure
occurred
while
inserting
cartridges
into
the
high-capacity
I/O
facility,
do
not
remove
the
cartridges.
Leave
the
cartridges
in
place,
and
the
operation
restarts
automatically.
Cartridges
inserted
in
the
convenience
I/O
station
that
remain
in
the
station
must
be
removed
from
the
station,
then
reinserted
after
the
Library
Manager
re-initializes.
4.
Notify
the
host
operator
that
the
switchover
is
complete.
5.
Continue
with
DFSMS
Host
Action
If
the
Library
Manager
has
been
varied
offline
because
of
the
failure,
when
the
Library
Manager
is
in
the
Auto
mode,
Online
state,
perform
the
following
actions
at
the
host:
Figure
282.
Library
Manager
Switching
Window
438
3494
Tape
Library
Operator
Guide
Содержание TotalStorage 3494 Tape Library
Страница 1: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Страница 2: ......
Страница 3: ...IBM TotalStorage 3494 Tape Library Operator Guide GA32 0449 14...
Страница 14: ...xii 3494 Tape Library Operator Guide...
Страница 22: ...xx 3494 Tape Library Operator Guide...
Страница 72: ...46 3494 Tape Library Operator Guide...
Страница 84: ...58 3494 Tape Library Operator Guide...
Страница 124: ...98 3494 Tape Library Operator Guide...
Страница 136: ...110 3494 Tape Library Operator Guide...
Страница 150: ...124 3494 Tape Library Operator Guide...
Страница 352: ...Figure 206 Service Window 326 3494 Tape Library Operator Guide...
Страница 536: ...510 3494 Tape Library Operator Guide...
Страница 572: ...546 3494 Tape Library Operator Guide...
Страница 580: ...554 3494 Tape Library Operator Guide...
Страница 600: ...574 3494 Tape Library Operator Guide...
Страница 603: ......
Страница 604: ...Part Number 95P6750 EC H79941 GA32 0449 14 1P P N 95P6750...
Страница 605: ...Spine information IBM TotalStorage 3494 Tape Library 3494 Tape Library Operator Guide...