background image

Combining high-performance architecture with high-performance Xeon processors

 

 

 

Please see the Legal Information section for important notices and information. 

2.5-inch SAS 

 

10,000

 RPMs — 73.4 or 

146.8GB 

(

587.2GB 

maximum 

per chassis;

 

2.349TB

 in a 4-chassis 

configuration)

 

 

15,000

 RPMs — 

73.4GB

 (

293.6GB

 per chassis; 

1.174TB

 per 4 chassis)

 

2-5-inch drives not only require less space than 3.5-inch drives, they 

weigh less, consume half 

the power, produce less noise, seek faster,

 and offer 

increased reliability

The hot-swap SAS drives use the Converged Tray for interchangeability with other IBM System 
x

 systems. If you need more storage space, terabyte capacities are possible with external 

direct-attach NAS and SAN solutions.

 

 

Integrated Virtualization 

Selected models of the x3850 M2 ship with an 

IBM 4GB USB 2.0 Flash Key

 installed preloaded 

with 

VMware ESXi 3.5

. This is an embedded version of VMware ESX 3.5, fully contained on the 

flash drive and requiring no disk space—not an “ESX Lite.” Rather than management through a 
Service Console based on a Linux operating system, ESXi 3.5 relies on aggregate management 
tools, including VirtualCenter, the Remote Command Line interface and the introduction of CIM 
for standards-based and agentless hardware monitoring. 
VMware ESXi 3.5 includes all the performance, scalability and compatibility features of ESX 3.5, 
including full 

VMFS

 support across FC SAN, iSCSI SAN, and NAS, and 

4-way VSMP

. Because 

it runs from flash memory, it’s extremely fast and ideal for diskless configurations. It also offers 
enhanced security, because it runs without an operating system-based console and is 
updated/patched much like firmware. Licensing works the same as for “standard” ESX 3.5. 
If you prefer 

Microsoft Hyper-V

 to VMware, the intent is for the x3850 M2 and x3950 M2 to 

fully support Microsoft’s hypervisor software installed on the system HDD at a future date. 

 

Disk/Tape Controllers 

All models include an integrated eight-port

 LSI 1078

 

Serial-Attach SCSI

 (SAS) controller. This 

controller supports up to 

four

 

internal

 SAS LVD (low-voltage differential) drives. 

The integrated SAS controller offers 

hardware

 

RAID-0

/

1

 support for those SAS drives. The

 

ServeRAID-MR10k

 option adds additional RAID levels, including 

RAID-10, 5, 50, 6 

and

 60

along with 

256MB

 of 

battery-backed cache

 memory for higher performance and data integrity, 

without

 consuming a valuable PCIe adapter slot. 

The 

SAS

 controller provides data transfer speeds of up to 

300MB

 per second

1

 in 

each

 direction 

(

full-duplex

) across the SAS bus, for an aggregate speed of 

600MBps

, nearly double that of 

Ultra320 SCSI’s 

320MBps

 (half-duplex) bandwidth. The serial design of the SAS bus allows 

maximum performance to be maintained as additional drives are added. 
Additional external SAS/SATA disk storage, as well as tape backup, is available using the 

external SAS port

 on the system unit, or via one of several supported iSCSI or FC SAN 

controllers.

 

 

Drive Bays 

The eX4 servers contain 

five

 drive bays (per chassis) in all—including 

four

 

2.5-inch

 HDD bays 

that support 

hot-swap SAS 

drives totaling up to 

587.6GB

.  

24X/10X/24X/8X

2

 speed (ultraslim, 0.5”) CD-RW/DVD-ROM combo drive with an IDE 

interface ships standard in all x3850 M2 and x3950 M2 servers. No floppy drive is supplied with 
any model; an external USB floppy drive may be used, if needed. 
For still more storage, a direct-attach, iSCSI, or FC SAN external expansion option can be 
added, using an optional controller. 

 

High-Performance Adapter Slots 

There are 

seven 

physical

 x8

 (“by 8”) 

PCIe (PCI Express)

 adapter slots standard (per chassis). 

Each is capable of supporting 

x4 

or

 x8

 adapters.

 

All slots are 

half-length/full-height

Electrically

 they are x8 slots as well (meaning that they operate at full

 x8

 

4GBps

 speeds). Slots

 

and

 7 

are 

Active PCIe hot-add/hot-swap 

slots, offering the capability to add or replace 

adapters without having to shut down the system. 

PCI Express

 is a high-performance, low-latency, next-generation serial I/O bus that is rapidly 

replacing the older parallel PCI and PCI-X buses. A 

x8

 PCIe adapter offers approximately 

four 

                                      

 

1

 Data transfer rates depend on many factors and are often less than the maximum possible. 

Содержание System x3850 M2

Страница 1: ...and running in a virtualized environment faster and easier than ever before IBM X Architecture pioneered XpandOnDemand pay as you grow scalability which allows chassis to be simply cabled together to...

Страница 2: ...nced features help maximize network availability by increasing uptime as do hot swap redundant HDDs power and fans Active Memory temperature controlled fans with Calibrated Vectored Cooling IPMI 2 0 s...

Страница 3: ...per core 80W quad core Xeon processor models E7320 at 2 13GHz with 64 bit extensions low power draw per core 20W quad 1066MHz FSBs and 4MB of L2 cache 2 x 2MB 1MB per core 80W dual core Xeon processor...

Страница 4: ...ther architectures Intel now offers a first generation snoop filter in their 7300 chipset however it contains only 64MB of RAM which is 80 smaller than the eX4 fourth generation solution Advanced Buff...

Страница 5: ...king latency In addition it also offers innovative data reliability and security features to help improve data integrity including enhanced CRC protection data retry on error detect and buffer registe...

Страница 6: ...SI SAS controller This controller supports up to four internal SAS LVD low voltage differential drives The integrated SAS controller offers hardware RAID 0 1 support for those SAS drives The ServeRAID...

Страница 7: ...n the proper ambient temperature When the temperature returns to a normal operating level the fans return to their default speed Why not simply run the fans at 100 capacity all the time For several go...

Страница 8: ...1000 SVGA video controller on the Remote Supervisor Adapter II provides up to 1024x768 resolution with a color depth of 32 bits at 85Hz refresh rate with 16MB of video memory Toolless slides Allows qu...

Страница 9: ...em temperature fans power supplies processor and DIMM status Fan speed control Product ID and Family ID detection Highly secure remote power on off System reset control NMI SMI detection and generatio...

Страница 10: ...and Capacity Manager sold separately are available as add ons for additional server management and increased availability IBM Systems Director provides a single uniform graphical interface for all of...

Страница 11: ...u take your servers to a higher level You can rely on System x options to supply a complete solution for your business needs Options help you create an optimized server system to meet your data protec...

Страница 12: ...tional integrated ServeRAID MR10k SAS SATA controller offers enhanced performance over the integrated LSI 1078 SAS controller 256MB of battery backed cache memory and supports seven RAID levels 0 stri...

Страница 13: ...ew Redundant H S Power Supply Bays PCIe Slots Video Port Scalability Ports Hot swap PCIe slots USB Ports Serial Port Remote Supervisor Adapter II Gb Ethernet Ports Hexagonal Ventilation Holes SAS Port...

Страница 14: ...r chassis Internal L2 cache 9MB 3 x 3MB 7233 7234 all 8MB 2 x 4MB 7141 7144 1xX 1xY 4xX 4xY 6MB 2 x 3MB 7141 7144 3xX 3xY 4MB 2 x 2MB 7141 7144 2xX 2xY External L3 cache 16MB shared cache 7233 6xX 6xY...

Страница 15: ...1 External disk drives supported standard Yes via external 4 port SAS connector External disk storage devices supported System Storage DS4100 DS4200 DS4300 DS4400 DS4500 DS4700 DS4800 DS6800 DS8100 DS...

Страница 16: ...ating systems supported 7141 7144 Microsoft Windows Server 2003 R2 Standard Web Enterprise Editions 32 64 bit RHEL 4 AS ES 32 64 bit RHEL 5 Server 32 64 bit SLES 9 10 32 64 bit VMware ESX Server 3 0 2...

Страница 17: ...AS drives internally and one external SAS port for optional external storage per chassis up to 16 drives in a 4 chassis configuration High performance external I O expansion Six 480Mbps USB 2 0 ports...

Страница 18: ...gal Information section for important notices and information 18 Hot swap redundant cooling Light path diagnostics front LED panel drop down light path panel Toolless chassis and toolless slide design...

Страница 19: ...emarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INC...

Отзывы: