![IBM System x3400 Type 7975 Скачать руководство пользователя страница 87](http://html2.mh-extra.com/html/ibm/system-x3400-type-7975/system-x3400-type-7975_installation-manual_4733445087.webp)
Table
7.
Abbreviated
list
of
POST
error
codes
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
the
parts
listing
in
the
Problem
Determination
and
Service
Guide
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
178
x
Fixed
disk
error.
Note:
x
is
the
drive
that
has
the
error.
1.
Run
the
hard
disk
drive
diagnostic
tests
on
drive
x
(see
“Running
the
diagnostic
programs”
in
the
Problem
Determination
and
Service
Guide
on
the
IBM
System
x3400
Documentation
CD).
2.
Reseat
the
following
components,
depending
on
the
server
model:
v
Hot-swap
and
non-hot-swap
models:
a.
Hard
disk
drive
x
b.
Hard
disk
drive
x
cable
c.
Optional
adapter
cable
d.
SAS/SATA
backplane
v
Simple-swap
models:
a.
Hard
disk
drive
x
b.
Hard
disk
drive
x
cable
c.
Optional
adapter
cable
d.
SATA
backplate
3.
Replace
the
following
components
one
at
a
time,
depending
on
the
server
model,
in
the
order
shown,
restarting
the
server
each
time:
v
Hot-swap
and
non-hot-swap
models:
a.
Hard
disk
drive
x
b.
Hard
disk
drive
cable
c.
Optional
adapter
cable
d.
SAS/SATA
backplane
v
Simple-swap
models:
a.
Hard
disk
drive
x
b.
Hard
disk
drive
x
cable
c.
SATA
backplate
4.
(Trained
service
technician
only)
Replace
the
system
board.
1800
Unavailable
PCI
hardware
interrupt.
1.
Run
the
Configuration/Setup
Utility
program
and
adjust
the
adapter
settings.
2.
Remove
each
adapter
one
at
a
time,
restarting
the
server
each
time,
until
the
problem
is
isolated.
Chapter
5.
Solving
problems
73
Содержание System x3400 Type 7975
Страница 3: ...System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 50: ...36 System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 58: ...44 System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 106: ...92 System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 116: ...102 System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 122: ...108 System x3400 Types 7973 7974 7975 and 7976 Installation Guide...
Страница 123: ......
Страница 124: ...Part Number 44W2583 Printed in USA 1P P N 44W2583...