Resolution
Perform “DR031: Resolve Robot Initialization Failure” on page 6-72.
T077: I/O Station Partially Partially Open
Description
GUI Description: The I/O station is in a partially open state or a cable
connection has failed.
Explanation: This ticket is specifically designed to report the problem that
would occur if the cable connecting any of the I/O stations is unplugged.
Hardware limitations make it such that and unplugged I/O and a partially
open I/O cannot be distinguished from one another. The default state of the
open and closed door sensors is such that only the partially open state looks
like the unplugged state (door not open + door not closed). The detection
logic will check for this condition only at boot up to avoid triggering the
ticket during any operational door open / close sequence.
Detection Scenario
Any time the library boots up it checks for the state of the I/O open and
close sensors to see if there is a not open and not closed condition.
Root Causes
1.
I/O station safety flap broken or loose.
2.
I/O station is unplugged at boot up
3.
I/O station is left in a not open and not closed state at boot up
Possible FRU Replacements
v
I/O Station Lock assembly
v
I/O station safety flap
v
Internal Cables and Boards Kit
Resolution
Perform “DR036: Resolve Partially Open I/O Station” on page 6-74.
T079: Get Operation Failed, Motion OK
Description
GUI Description: The robot failed to pick a tape cartridge.
Explanation; The library cannot successfully get a tape from a drive, storage
or I/O location. The tape is still resting in the source location. The robot is
not obstructed in any way and can continue operations (unlike the case for
T003). If the operation was initiated by a host move media, the move media
command has failed with an ASC/ASCQ of 4h/15h/01h (hardware
mechanical positioning error).
Detection Scenario
The picker cannot get a tape from the source location. It can scan or touch
the tape to verify that it is present.
Root Causes
1.
Picker has broken fingers.
2.
Picker has bad calibration so it is not positioned correctly.
3.
Picker has bad
'y'
gears so it is not at the height it thinks it is at.
4.
An obstruction that prevents the picker fingers from getting into the tape
grooves.
5.
A bad tape that is jammed and stuck in the slot.
6.
A damaged slot or drive that will not release the tape.
Possible CRU Replacements
v
Cartridge
Possible FRU Replacements
v
Picker
v
Y-axis assembly
v
Column assembly
Resolution
Perform “DR076: Resolve Get Failure” on page 6-82.
Chapter 6. Service Action Tickets (Txxx) and Diagnostic Resolutions (DRxxx)
6-35
Содержание System Storage TS3310
Страница 2: ......
Страница 6: ...iv TS3310 Tape Library Maintenance Information...
Страница 8: ...vi TS3310 Tape Library Maintenance Information...
Страница 18: ...xvi TS3310 Tape Library Maintenance Information...
Страница 20: ...xviii TS3310 Tape Library Maintenance Information...
Страница 22: ...xx TS3310 Tape Library Maintenance Information...
Страница 28: ...1 6 TS3310 Tape Library Maintenance Information...
Страница 70: ...1 Home Sensor Flag a66mi080 1 Figure 3 11 Home Sensor Flag 3 8 TS3310 Tape Library Maintenance Information...
Страница 76: ...3 14 TS3310 Tape Library Maintenance Information...
Страница 92: ...4 16 TS3310 Tape Library Maintenance Information...
Страница 196: ...6 94 TS3310 Tape Library Maintenance Information...
Страница 242: ...7 46 TS3310 Tape Library Maintenance Information...
Страница 300: ...1 2 a66mi015 Figure 8 58 Guide rollers on Y axis Picker Assembly 8 58 TS3310 Tape Library Maintenance Information...
Страница 378: ...8 136 TS3310 Tape Library Maintenance Information...
Страница 382: ...9 4 TS3310 Tape Library Maintenance Information...
Страница 390: ...10 8 TS3310 Tape Library Maintenance Information...
Страница 396: ...A 6 TS3310 Tape Library Maintenance Information...
Страница 414: ...Control Module and Expansion Module Electrical System a66mi037 C 6 TS3310 Tape Library Maintenance Information...
Страница 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Страница 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Страница 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Страница 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Страница 421: ...a66mi036 Appendix C Library Diagrams C 13...
Страница 422: ...Library Cables Library System Grounding a66mi041 C 14 TS3310 Tape Library Maintenance Information...
Страница 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Страница 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Страница 484: ...D 60 TS3310 Tape Library Maintenance Information...
Страница 494: ...E 10 TS3310 Tape Library Maintenance Information...
Страница 498: ...F 4 TS3310 Tape Library Maintenance Information...
Страница 504: ...G 6 TS3310 Tape Library Maintenance Information...
Страница 520: ...H 16 TS3310 Tape Library Maintenance Information...
Страница 526: ...X 6 TS3310 Tape Library Maintenance Information...
Страница 529: ......
Страница 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...
Страница 531: ...Spine information IBM System Storage TS3310 Tape Library TS3310 Tape Library Maintenance Information Machine Type 3576...