Resolution
Before performing the following:
v
“Removing a Drive Sled” on page 8-43.
v
“Replacing a Drive Sled” on page 8-44.
refer to Chapter 1, “Start Service,” on page 1-1 for additional diagnostic
procedures.
v
Perform “DR049: Resolve Drive TapeAlert 30, 31 - Drive Hardware Error”
on page 6-79.
v
From the Operator Panel, select
Tools
→
Service
→
Drives
to run the drive
diagnostic. A blank, scratch cartridge is required for this test.
T050: Drive TapeAlert 31 - Hardware B
Description
GUI Description: The tape drive detected an internal hardware problem.
Explanation: System determines that the drive has issued a TapeAlert 31
indicating a hardware error that requires a drive power cycle before the
drive might recover to a usable state.
Detection Scenario
Tape drive issues a TapeAlert 31 which is recognized by the library during
the continuous four second polling cycle of drive status.
Root Causes
Drive has determined that there is a problem per its internal algorithms.
Possible CRU Replacements
Drive Sled
Resolution
v
Perform “DR049: Resolve Drive TapeAlert 30, 31 - Drive Hardware Error”
on page 6-79.
v
From the Operator Panel, select
Tools
→
Service
→
Drives
to run the drive
diagnostic. A blank, scratch cartridge is required for this test.
T051: Drive TapeAlert 32 - Interface
Description
GUI Description: The tape drive reported an external data interface problem
Explanation: System determines that the drive has issued a TapeAlert 32
indicating a tape drive has detected a problem with the application client
interface.
Detection Scenarios
Tape drive issues a TapeAlert 32 which is recognized by the library during
the continuous four second polling cycle of drive status.
Root Causes
Drive has determined that there is a problem per its internal algorithms.
Possible CRU Replacements
Drive Sled(only if all cables are OK and host communication to other drives
works)
Resolution
1.
Perform “DR012: Resolve Drive Tape Alert 32 - Host Interface” on page
6-65.
2.
Use the "Details" option in the RAS ticket to identify which tape drive
reported the RAS ticket.
3.
Clear the RAS ticket.
4.
Check the cabling from the back of the tape drive to the host and reseat
all the cables.
5.
If RAS ticket persists, swap cables between drives to isolate a bad cable.
If this works and you can detect the drive, replace the bad cable.
6.
If swapping cables did not fix the problem, then upgrade the tape drive
to the latest drive firmware.
6-24
TS3310 Tape Library Maintenance Information
Содержание System Storage TS3310
Страница 2: ......
Страница 6: ...iv TS3310 Tape Library Maintenance Information...
Страница 8: ...vi TS3310 Tape Library Maintenance Information...
Страница 18: ...xvi TS3310 Tape Library Maintenance Information...
Страница 20: ...xviii TS3310 Tape Library Maintenance Information...
Страница 22: ...xx TS3310 Tape Library Maintenance Information...
Страница 28: ...1 6 TS3310 Tape Library Maintenance Information...
Страница 70: ...1 Home Sensor Flag a66mi080 1 Figure 3 11 Home Sensor Flag 3 8 TS3310 Tape Library Maintenance Information...
Страница 76: ...3 14 TS3310 Tape Library Maintenance Information...
Страница 92: ...4 16 TS3310 Tape Library Maintenance Information...
Страница 196: ...6 94 TS3310 Tape Library Maintenance Information...
Страница 242: ...7 46 TS3310 Tape Library Maintenance Information...
Страница 300: ...1 2 a66mi015 Figure 8 58 Guide rollers on Y axis Picker Assembly 8 58 TS3310 Tape Library Maintenance Information...
Страница 378: ...8 136 TS3310 Tape Library Maintenance Information...
Страница 382: ...9 4 TS3310 Tape Library Maintenance Information...
Страница 390: ...10 8 TS3310 Tape Library Maintenance Information...
Страница 396: ...A 6 TS3310 Tape Library Maintenance Information...
Страница 414: ...Control Module and Expansion Module Electrical System a66mi037 C 6 TS3310 Tape Library Maintenance Information...
Страница 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Страница 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Страница 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Страница 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Страница 421: ...a66mi036 Appendix C Library Diagrams C 13...
Страница 422: ...Library Cables Library System Grounding a66mi041 C 14 TS3310 Tape Library Maintenance Information...
Страница 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Страница 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Страница 484: ...D 60 TS3310 Tape Library Maintenance Information...
Страница 494: ...E 10 TS3310 Tape Library Maintenance Information...
Страница 498: ...F 4 TS3310 Tape Library Maintenance Information...
Страница 504: ...G 6 TS3310 Tape Library Maintenance Information...
Страница 520: ...H 16 TS3310 Tape Library Maintenance Information...
Страница 526: ...X 6 TS3310 Tape Library Maintenance Information...
Страница 529: ......
Страница 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...
Страница 531: ...Spine information IBM System Storage TS3310 Tape Library TS3310 Tape Library Maintenance Information Machine Type 3576...