Chapter 1. Start Service
Problem Area
If...
Then...
Error Message
Your library issues an
Operator Intervention...
You will know when an
Operator Intervention has been
issued when the
Library
,
Drives
, or
Media
button at the
bottom of the Operator Panel
screen turns yellow or red.
Operator Interventions are also
indicated by the amber
Operator Intervention Alert
LED on the front panel of the
library to the right of the
power button, or by e-mail
notifications, if this feature is
enabled.
v
Touch the
Library
,
Drives
, or
Media
button at the bottom
of the Operator Panel screen, then touch
Operator
Interventions
to view the error message(s).
v
After reading an error message, touch the
Resolve
button to
display the suggested resolution for the problem.
v
Refer to Chapter 6, “Service Action Tickets (Txxx) and
Diagnostic Resolutions (DRxxx),” on page 6-1 for more
information about the Service Action Ticket number (T
xxx
).
The resolution for an
Operator Intervention
suggests a CRU or FRU
replacement...
Before replacing a CRU or FRU:
v
Refer to Chapter 6, “Service Action Tickets (Txxx) and
Diagnostic Resolutions (DRxxx),” on page 6-1 for additional
information on resolving the problem.
v
Observe the LEDs on all components (For more
information, see “Interpreting LEDs” on page 7-16.). If the
LEDs on a component indicate that there is a problem,
reseat the component.
v
Visually check, and reseat if necessary, all of the cables that
are connected to the failing FRU or CRU. For more
information, see “Checking/Reseating Cables” on page 7-29.
v
If possible, power cycle the library.
v
If the error occurs again, replace the suspect component.
A TapeAlert message was
received...
Refer to Appendix A, “TapeAlert Flags Supported by the
Drive,” on page A-1.
You are experiencing a
problem with your library
and no Operator Intervention
was created...
If after trying all diagnostic procedures you are unable to
resolve the problem, contact your next level of support.
The Operator Panel displays,
"Error - cannot Determine
Personality"...
1.
Power cycle the library.
2.
If the same message appears, replace the Compact Flash
Card (see “Library Control Blade or Compact Flash Card”
on page 8-45.
You get repeated errors,
multiple functions surface
failure messages, or T
xxx
codes...
Open and close an Access Door to ensure that all previous
error handling is completed and to enable normal library
robotic function.
© Copyright IBM Corp. 2005, 2010
1-1
Содержание System Storage TS3310
Страница 2: ......
Страница 6: ...iv TS3310 Tape Library Maintenance Information...
Страница 8: ...vi TS3310 Tape Library Maintenance Information...
Страница 18: ...xvi TS3310 Tape Library Maintenance Information...
Страница 20: ...xviii TS3310 Tape Library Maintenance Information...
Страница 22: ...xx TS3310 Tape Library Maintenance Information...
Страница 28: ...1 6 TS3310 Tape Library Maintenance Information...
Страница 70: ...1 Home Sensor Flag a66mi080 1 Figure 3 11 Home Sensor Flag 3 8 TS3310 Tape Library Maintenance Information...
Страница 76: ...3 14 TS3310 Tape Library Maintenance Information...
Страница 92: ...4 16 TS3310 Tape Library Maintenance Information...
Страница 196: ...6 94 TS3310 Tape Library Maintenance Information...
Страница 242: ...7 46 TS3310 Tape Library Maintenance Information...
Страница 300: ...1 2 a66mi015 Figure 8 58 Guide rollers on Y axis Picker Assembly 8 58 TS3310 Tape Library Maintenance Information...
Страница 378: ...8 136 TS3310 Tape Library Maintenance Information...
Страница 382: ...9 4 TS3310 Tape Library Maintenance Information...
Страница 390: ...10 8 TS3310 Tape Library Maintenance Information...
Страница 396: ...A 6 TS3310 Tape Library Maintenance Information...
Страница 414: ...Control Module and Expansion Module Electrical System a66mi037 C 6 TS3310 Tape Library Maintenance Information...
Страница 415: ...Library Electrical Block a66mi038 Appendix C Library Diagrams C 7...
Страница 416: ...Library Control Blade a66mi042 C 8 TS3310 Tape Library Maintenance Information...
Страница 417: ...Library Control Blade Functions a66mi039 Appendix C Library Diagrams C 9...
Страница 418: ...Accessor Control Block a66mi040 C 10 TS3310 Tape Library Maintenance Information...
Страница 421: ...a66mi036 Appendix C Library Diagrams C 13...
Страница 422: ...Library Cables Library System Grounding a66mi041 C 14 TS3310 Tape Library Maintenance Information...
Страница 423: ...Library Power System a66mi044 Appendix C Library Diagrams C 15...
Страница 424: ...a66mi043 C 16 TS3310 Tape Library Maintenance Information...
Страница 484: ...D 60 TS3310 Tape Library Maintenance Information...
Страница 494: ...E 10 TS3310 Tape Library Maintenance Information...
Страница 498: ...F 4 TS3310 Tape Library Maintenance Information...
Страница 504: ...G 6 TS3310 Tape Library Maintenance Information...
Страница 520: ...H 16 TS3310 Tape Library Maintenance Information...
Страница 526: ...X 6 TS3310 Tape Library Maintenance Information...
Страница 529: ......
Страница 530: ...Part Number 46X4072 Printed in USA GA32 0478 08 1P P N 46X4072...
Страница 531: ...Spine information IBM System Storage TS3310 Tape Library TS3310 Tape Library Maintenance Information Machine Type 3576...