manualshive.com logo in svg
background image

4.

   

Plug

 

the

 

network

 

ethernet

 

cable

 

2

   

in

 

Figure

 

1-12

 

on

 

page

 

1-10

 

or

 

Figure

 

1-13

 

on

 

page

 

1-10)

 

into

 

the

 

ethernet

 

port

 

on

 

the

 

back

 

panel

 

of

 

the

 

library.

 

If

 

the

 

ethernet

 

connection

 

is

 

directly

 

attached

 

to

 

a

 

server

 

or

 

laptop,

 

a

 

crossover

 

ethernet

 

cable

 

may

 

be

 

required.

Installing

 

a

 

Fibre

 

Channel

 

Interposer

 

(Feature

 

Code

 

5096)

 

For

 

a

 

list

 

of

 

supported

 

adapters

 

and

 

required

 

interposers,

 

go

 

to

 

the

 

Technical

 

Support

 

section

 

on

 

the

 

web

 

at

 

http://www.ibm.com/storage/lto.

 

To

 

install

 

the

 

interposer,

 

refer

 

to

 

Figure

 

1-14

 

and

 

the

 

procedure

 

below.

 

 

1.

   

Connect

 

the

 

host

 

SC

 

fibre

 

cable

 

to

 

the

 

matching

 

side

 

of

 

the

 

interposer.

 

2.

   

Connect

 

the

 

drive

 

LC

 

fibre

 

side

 

of

 

the

 

interposer

 

to

 

the

 

drive/library.

Connecting

 

a

 

Power

 

Cord

 

Attention:

   

This

 

product

 

can

 

ONLY

 

be

 

used

 

with

 

an

 

approved

 

power

 

cord

 

for

 

your

 

specific

 

geographic

 

region.

 

Use

 

of

 

an

 

unapproved

 

power

 

cord

 

may

 

result

 

in:

 

v

   

not

 

meeting

 

individual

 

country

 

specific

 

safety

 

requirements;

 

v

   

overheating

 

with

 

potential

 

personal

 

injury

 

and/or

 

property

 

damage;

 

and

 

v

   

a

 

fracture

 

resulting

 

in

 

the

 

internal

 

contacts

 

being

 

exposed,

 

which

 

potentially

 

could

 

subject

 

the

 

user

 

to

 

a

 

shock

 

hazard.

1.

   

Plug

 

one

 

end

 

of

 

the

 

power

 

cord

 

(

4

   

in

 

Figure

 

1-12

 

on

 

page

 

1-10

 

or

 

Figure

 

1-13

 

on

 

page

 

1-10)

 

into

 

the

 

power

 

connector

 

on

 

the

 

back

 

panel

 

of

 

the

 

library.

 

2.

   

Plug

 

the

 

other

 

end

 

of

 

the

 

power

 

cord

 

into

 

the

 

nearest

 

properly

 

grounded

 

power

 

outlet.

 

 

Attention:

   

To

 

disconnect

 

all

 

power

 

from

 

the

 

library,

 

remove

 

the

 

power

 

cord

 

from

 

the

 

outlet.

 

The

 

power

 

button

 

only

 

puts

 

the

 

power

 

on

 

stand-by.

 

3.

   

Turn

 

ON

 

the

 

library

 

using

 

the

 

power

 

button.

 

Check

 

the

 

Operator

 

Control

 

Panel

 

display

 

to

 

make

 

sure

 

the

 

library

 

is

 

receiving

 

power.

 

If

 

it

 

is

 

not,

 

check

 

the

 

power

 

connections

 

and

 

your

 

power

 

source.

 

During

 

the

 

Power-On

 

Self

 

Test

 

(POST),

 

all

 

four

 

LEDs

 

are

 

illuminated

 

briefly,

 

followed

 

by

 

a

 

flashing

 

Ready

 

LED.

 

When

 

the

 

initialization

 

sequence

 

is

 

complete,

 

the

 

Home

 

screen

 

will

 

be

 

displayed.

a67m0276

Host

Fibre

Channel

Network

Library

Fibre

Channel

Drive

Connector

11P1373

  

Figure

 

1-14.

 

Interposer

 

installation

 

Installation

 

1-11

Содержание System Storage TS3100

Страница 1: ...IBM System Storage TS3100 Tape Library and TS3200 Tape Library Installation Quick Reference Machine Type 3573 GA32 0548 00...

Страница 2: ......

Страница 3: ...IBM System Storage TS3100 Tape Library and TS3200 Tape Library Installation Quick Reference Machine Type 3573 GA32 0548 00...

Страница 4: ...at http www ibm com storage lto Second Edition June 2006 This edition applies to the IBM System Storage TS3100 Tape Library and TS3200 Tape Library Installation Quick Reference GA32 0548 00 and to the...

Страница 5: ...the Library for Rack Installation ONLY 1 4 Attaching the Library to a Server 1 9 Connecting the Host Interface Cable 1 9 Connecting a Power Cord 1 11 Preparing the Host 1 12 Verifying the Connection 1...

Страница 6: ...iv TS3100 and TS3200 3573 Installation Quick Reference...

Страница 7: ...ople because of some existing condition The following are examples of caution notices A hazardous electrical condition with less severity than electrical danger A generally hazardous condition not rep...

Страница 8: ...led in a different rack cabinet v An electrical outlet that is not correctly wired could place hazardous voltage on the metal parts of the system or the devices that attach to the system It is the res...

Страница 9: ...e that the four leveling pads are raised to their highest position v Ensure that there is no stabilizer bracket installed on the rack cabinet during movement v Do not use a ramp inclined at more than...

Страница 10: ...ironment and human health due to the potential presence of hazardous substances in EEE For proper collection and treatment contact your local IBM representative Battery Return Program This product may...

Страница 11: ...nches v Sides Minimum of 5 08 cm 2 inches Rack requirements Standard 19 inch rack with v 2U 63 5 mm 3 5 in of clearance for a 2U library v 4U 177 8 mm 7 in of clearance for a 4U library Rackmounting t...

Страница 12: ...nal item that is included in your shipment if ordered Rack Mount Kit Important If any of the contents of your shipment are damaged or missing please call the appropriate number listed on the Quality H...

Страница 13: ...ON The shipping lock is held in place with a label and is located in the top center of the library After the shipping lock is removed it should be stored on the right side of the back panel of the li...

Страница 14: ...ndard 19 inch rack system The 2U library requires 2U 3 5 in of space The 4U library requires 4U 7 in of space If you are not rackmounting your library skip this procedure and go to Attaching the Libra...

Страница 15: ...install your library in a rack perform the following steps 1 Verify that your rack kit includes the following contents see Figure 1 4 v Packaged in plastic material 2 rails 2 mounting brackets v Packa...

Страница 16: ...front and back of each rail to the rack The rails extend to fit a variety of rack depths Each rail requires 2U of rack space 1 in Figure 1 5 4 Using the Torx wrench included in your shipment remove t...

Страница 17: ...ith library rack anchors and mounting brackets installed slide the library onto the rails as shown in Figure 1 8 and Figure 1 9 on page 1 8 When the library stops gently push the library to lock the a...

Страница 18: ...e Figure 1 11 on page 1 9 for a 4U library by placing a screw in the center hole of each mounting bracket and tightening them 1 a77ug109 Figure 1 9 Sliding the 4U library into the rack a77ug112 1 Figu...

Страница 19: ...the server and all attached accessories Important Failure to remove the power cords from these devices before connecting the host interface cable could result in damage to the library 2 For a SCSI lib...

Страница 20: ...cables and terminators specified for Ultra160 or Ultra320 use or labeled as Multi Mode should be used Note The host bus adapter should be LVD SCSI A single ended SE SCSI host bus adapter will work bu...

Страница 21: ...requirements v overheating with potential personal injury and or property damage and v a fracture resulting in the internal contacts being exposed which potentially could subject the user to a shock h...

Страница 22: ...erminated Likewise if the library is physically the last SCSI device on the SCSI bus it must be terminated Only the devices physically located at the beginning and end of the SCSI bus should be termin...

Страница 23: ...ol as your library network setting complete Steps 1 2 3 and 7 If you do not want to use DHCP as your library network setting complete Steps 1 2 4 5 6 and 7 1 Press the DOWN button to highlight the Net...

Страница 24: ...1 18 6 Entering Date and Time using the Web User Interface on page 1 18 7 Entering Control Path Failover License Activation Key on page 1 19 8 Configuring Logs and Traces using the Web User Interface...

Страница 25: ...ge in any order Sequential In sequential mode the library s firmware predefines the selection of the cartridges After initialization the firmware causes the library to select the first available cartr...

Страница 26: ...r each drive listed either SCSI or Fibre Channel Refer to Figure 1 19 on page 1 17 3 Click one of the following v Refresh to update the current screen v Submit to apply the changes made to the screen...

Страница 27: ...dress Network Mask and Gateway Address IP Address An identifier for a computer or device on a TCP IP network Networks using the TCP IP protocol route messages based on the IP address of the destinatio...

Страница 28: ...Access PIN Code enter the personal identification number again 8 In Support Name enter the name of the person that will be able to offer the user help with the library 9 In Support Phone enter the pho...

Страница 29: ...races using the Web User Interface This function is not available on the Operator Control Panel 1 Click Logs Traces in the left navigation pane 2 It is recommended that you select Continuous so all in...

Страница 30: ...like to be notified when a warning occurs select Notify Warnings 3 In To Email Address enter the email address to which the information will be sent 4 In Email Domain enter the domain name for the ema...

Страница 31: ...l Panel on page 1 23 8 Restoring Factory Default Settings using the Operator Control Panel on page 1 23 Choosing the Number of Logical Libraries 1 Navigate to Configure Logical Libraries 2 Press the D...

Страница 32: ...the Netmask field b Press the UP or DOWN button to select the digit s in your library s Netmask address c Press the ENTER button to highlight the next digit s in your library s Netmask address d Afte...

Страница 33: ...After entering the final digit press the DOWN button and select one of the following v Save to apply your settings v Cancel to delete your settings Restoring Factory Default Settings using the Operat...

Страница 34: ...t magazine To open the I O Station select Control Open I O Station The I O Station will pop open To close the I O Station gently push it back into the left magazine a77ug020 Figure 1 27 2U library lef...

Страница 35: ...rage slots The lower left magazine has nine storage slots and houses the 3 slot I O Station 1 in Figure 1 30 on page 1 26 The upper right magazine has twelve storage slots The lower right magazine has...

Страница 36: ...a77ug105 1 Figure 1 30 4U library left magazines 1 26 TS3100 and TS3200 3573 Installation Quick Reference...

Страница 37: ...n page 1 28 is part of the lower left magazine To open the I O Station select Control Open I O Station The I O Station will pop open To close the I O Station gently push it back into the lower left ma...

Страница 38: ...e Library with Data Cartridges For information on working with the cartridge magazines see Cartridge Magazines on page 1 23 1 Unlock the cartridge magazines a77ug103 Figure 1 32 4U library I O Station...

Страница 39: ...CS This slot holds the cleaning cartridge In a 2U library the cleaning cartridge can be placed in any storage slot With the Auto Clean feature enabled a drive will be cleaned automatically when necess...

Страница 40: ...1 30 TS3100 and TS3200 3573 Installation Quick Reference...

Страница 41: ...ied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applicable to your tasks h h h h h Please tell us how we can im...

Страница 42: ...pment Department GZW 9000 South Rita Road Tucson Arizona U S A 85775 4401 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 43: ......

Страница 44: ...Part Number 23R7508 Printed in USA GA32 0548 00 1P P N 23R7508...

Страница 45: ...Spine information IBM System Storage TS3100 Tape Library and TS3200 Tape Library TS3100 and TS3200 3573 Installation Quick Reference Machine Type 3573...

Отзывы: