background image

1

Unpacking the EXN2000 (expansion unit)

EXN2000

(expansion unit)

Note:

The contents of the box will differ based

on the model you purchased. See Step 1.1 for a
list of contents for specific models.

1

2

Important:

If your system was shipped already assembled and cabled in a rack, go
directly to the

for the storage system to

boot the system.

Installation and Setup Instructions

Accessory kit:

- IBM rail kit
- Power cables
- Setup kit

Содержание System Storage EXN2000

Страница 1: ...EXN2000 Installation and Setup Instructions IBM System Storage...

Страница 2: ......

Страница 3: ...on Unit Hardware and Service Guide IBM System Storage EXN1000 and EXN2000 Installation and Setup Instructions Note r Need help If you encounter any difficulties while setting up your system contact IB...

Страница 4: ...on the model you purchased See Step 1 1 for a list of contents for specific models 1 2 Important If your system was shipped already assembled and cabled in a rack go directly to the for the storage sy...

Страница 5: ...tems EXN2000 2863 001 1 EXN2000 1 Publications 2 Power cords ables May be present 1 IBM rail kit 1 Wrist strap ESD 1 Enclosure shelf Ids label Miscellaneous data c Small Form Factor Pluggable SFP modu...

Страница 6: ...s Use the figure on the next page for reference At the front of the rack position the right hand rail into the rack at the appropriate EIA location make sure that the two locating pins seat properly T...

Страница 7: ...ighten the four rail adjustment screws on the installed rail 2 5 Repeat steps 2 2 through 2 4 for the left hand rail 2 6 Repeat steps 2 1 through 2 5 if installing a second EXN2000 Section of rack EIA...

Страница 8: ...e shelf IDs before installing into the rack All shelf IDs should be correct and sequential in the individual loop s If the filer and expansion unit were configured together by manufacturing these IDs...

Страница 9: ...must be set to the 1Gb position If connecting to an N5000 series or an N7000 series storage system the speed switch must be set to the 2Gb position Use the following diagram for reference Setting the...

Страница 10: ...pply receptacles as indicated by a ground symbol at the back of the expansion unit using the M5 x 0 5 inch screw If additional expansion units need to be grounded continue attaching the grounding cabl...

Страница 11: ...are being installed by holding the wire clamp up plugging in the power cord and lowering the clamp to secure the power cord 6 3 Connect the power cords to the power sources making sure that the power...

Страница 12: ...module Input port Repeat as needed Make sure that the cables are secure for example for example Out In Out In B A Out In Out In B A 1 ID x 2 3 for example ID x 1 2 for example ID x 1 for example To F...

Страница 13: ...orage N5000 Series Hardware and Service Guide IBM System Storage EXN2000 Hardware and Service Guide IBM System Storage N series Introduction and Planning Guide IBM Translated Safety Notices IBM System...

Страница 14: ...ication to IBM products or services do not imply that IBM intends to make them available in every country or region IBM the IBM logo and System Storage are trademarks and or registered trademarks of I...