Replacing the release tab on a controller or power supply
The miscellaneous hardware kit contains two replacement release tabs: one for a
power supply and one for a controller or controller filler panel. Obtain a
miscellaneous hardware kit if you have to replace a release tab (see Table 6 on
page 102).
Before you replace a release tab, read the following important information:
v
In this procedure, the term
controller
refers to a controller or controller filler panel.
v
Make sure that you have a size #1 or #0 Phillips screwdriver.
To replace a release tab, complete the following steps:
1. Read the safety information that begins on page xi and “Best practices
guidelines” on page 6.
2. Make sure that it is safe to proceed:
v
If you are replacing the release tab on the only controller in the DS3300,
make sure that the DS3300 is shut down for maintenance.
v
If you are replacing a power-supply release tab, make sure that the power
supplies are providing redundant power (on both power supplies, the ac
power LED and dc power LEDs are lit, and the fault LED is off). If the power
supplies are not providing redundant power, resolve the redundancy problem
first, or wait until the DS3300 is shut down for maintenance, before you
replace the release tab.
3. Remove the controller or power supply from the DS3300 chassis. See
“Removing a controller” on page 63 or “Replacing a power supply” on page 79.
Controller release tab
Power-supply release tab
Alignment pins
Alignment pins
Arrow
Arrow
Figure 52. Controller and power supply release tabs
Chapter 5. Replacing components
91
Содержание System Storage DS3300
Страница 1: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 2: ......
Страница 3: ...System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 8: ...vi System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 12: ...x System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 15: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 Safety xiii...
Страница 40: ...22 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 60: ...42 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 80: ...62 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 118: ...100 System Storage DS3300 Storage Subsystem Installation User s and Maintenance Guide...
Страница 139: ......
Страница 140: ...Part Number 46M1393 Printed in USA 1P P N 46M1393...