SurePOS 500 4846-XX5 Technical Reference
Page 35 of 63
4.0 Environmental
Specifications
4.1 Temperature/Humidity
Limits
Condition
Temp Limits (Dry Bulb)
Relative Humidity
Max. Wet Bulb Temp
Operating / Standby
5 to 40°
8 to 80 %
27°C
Storage (packaged)
0 to 60°C
5 to 80 %
29°C
Shipment (packaged)
-40 to 60°C
5 to 100 %
29°C
4.2 Altitude
Limits
The product is designed to operate up to 3050 meters (10,000 feet).
4.3 Power
Off (attached to mains)
4W
Suspend Not
supported
Standby 80W
On (idle)
120W
Power Consumption
(system)
On (max)
170W
Input Voltage
100 - 127, 200 - 240 VAC (nominal), 50 or 60 Hz (+/- 3 Hz)
Sinusoidal, trapezoidal, or square wave inputs
kVA 0.3
AC Input Connector/Cable
IEC 320 C14, unshielded right angle type
Leakage current
3.5 mA maximum
Inrush
< 30 A (peak, first cycle)
4.4 Acoustics
Measurement Operator
-Idle
LwAu (bels)
5.0
All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.
4.5 Standards
Compliance
4.5.1 Product
Certifications
Category Standard
External Safety
•
IEC
60950-1
1
st
Edition with all national deviations
•
UL 60950-1 1
st
Edition
•
CAN/CSA C22.2 No. 60950-1 3
rd
Edition
•
CCC
(China)
•
IRAM
(Argentina)
•
PSE
(Japan)
•
GOST
(Russia)
•
BSMI
(Taiwan)
Electrostatic Discharge (ESD)