background image

CAUTION:
Removing components from the upper positions in the rack cabinet improves
rack stability during a relocation. Follow these general guidelines whenever you
relocate a populated rack cabinet within a room or building.

v

Reduce the weight of the rack cabinet by removing equipment starting at the
top of the rack cabinet. When possible, restore the rack cabinet to the
configuration of the rack cabinet as you received it. If this configuration is not
known, you must observe the following precautions.

– Remove all devices in the 32U position and above.

Ensure that the heaviest devices are installed in the bottom of the rack

cabinet.

– Ensure that there are no empty U-levels between devices installed in the

rack cabinet below the 32U level.

v

If the rack cabinet you are relocating is part of a suite of rack cabinets, detach
the rack cabinet from the suite.

v

If the rack cabinet you are relocating was supplied with removable outriggers
they must be reinstalled before the cabinet is relocated.

v

Inspect the route that you plan to take to eliminate potential hazards.

v

Verify that the route that you choose can support the weight of the loaded
rack cabinet. Refer to the documentation that comes with your rack cabinet for
the weight of a loaded rack cabinet.

v

Verify that all door openings are at least 760 x 230 mm (30 x 80 in.).

v

Ensure that all devices, shelves, drawers, doors, and cables are secure.

v

Ensure that the four leveling pads are raised to their highest position.

v

Ensure that there is no stabilizer bracket installed on the rack cabinet during
movement.

v

Do not use a ramp inclined at more than 10 degrees.

v

When the rack cabinet is in the new location, complete the following steps:

– Lower the four leveling pads.

– Install stabilizer brackets on the rack cabinet.

– If you removed any devices from the rack cabinet, repopulate the rack

cabinet from the lowest position to the highest position.

v

If a long-distance relocation is required, restore the rack cabinet to the
configuration of the rack cabinet as you received it. Pack the rack cabinet in
the original packaging material, or equivalent. Also lower the leveling pads to
raise the casters off the pallet and bolt the rack cabinet to the pallet.

(R002)

CAUTION:

v

Rack is not intended to serve as an enclosure and does not provide any
degrees of protection required of enclosures.

v

It is intended that equipment installed within this rack will have its own
enclosure. (R005).

CAUTION:
Tighten the stabilizer brackets until they are flush against the rack. (R006)

CAUTION:
Use safe practices when lifting. (R007)

vi

IBM Storwize V7000 Unified: Model 2073-720 Quick Installation Guide

Содержание Storwize V7000

Страница 1: ...IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide GC27 5945 01...

Страница 2: ...as the information in the IBM Environmental Notices and User Guide which is provided on a DVD This edition applies to IBM Storwize V7000 Unified and to all subsequent releases and modifications until...

Страница 3: ...afety Notices with the user publications that were provided with the Storwize V7000 Unified hardware 3 Find the matching identification number in the IBM Systems Safety Notices Then review the topics...

Страница 4: ...end of each caution notice or each danger notice In the following examples the numbers D002 and C001 are the identification numbers DANGER A danger notice indicates the presence of a hazard that has...

Страница 5: ...ed for air flow through the unit v Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does not compromise the supply wiring or o...

Страница 6: ...binet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x 230 mm 30 x 80 in v Ensure that all devices shelves drawers doors and cables are secure v Ensure that t...

Страница 7: ...he same model rack should be coupled together with another same model rack R009 Danger notices for Storwize V7000 Unified Ensure that you are familiar with the danger notices for Storwize V7000 Unifie...

Страница 8: ...t or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and mode...

Страница 9: ...re to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing v Connect all devices installed in a rack cabinet to power devices installed in the same rack ca...

Страница 10: ...upplied and address specific issues relevant to the equipment provided General safety When you service the Storwize V7000 Unified follow general safety guidelines Use the following general rules to en...

Страница 11: ...electrostatic discharge observe the following precautions v Limit your movement Movement can cause static electricity to build up around you v Handle the device carefully holding it by its edges or fr...

Страница 12: ...ents on limitations product information product recycling and disposal battery information flat panel display refrigeration and water cooling systems external power supplies and safety data sheets To...

Страница 13: ...The information center is available at the following website publib boulder ibm com infocenter storwize unified_ic index jsp Storwize V7000 Unified library Unless otherwise noted the publications in...

Страница 14: ...uide provides instructions for unpacking your shipping order and installing the 2076 expansion enclosure for the Storwize V7000 Unified system GC27 4234 Adding Storwize V7000 Unified File modules to a...

Страница 15: ...ified File modules to an Existing Storwize V7000 System SC27 5415 IBM Statement of Limited Warranty 2145 and 2076 This multilingual document provides information about the IBM warranty for machine typ...

Страница 16: ...d from the Adobe website www adobe com support downloads main html How to order IBM publications The IBM Publications Center is a worldwide central repository for IBM product publications and marketin...

Страница 17: ...l assistance or just want more information about IBM products you will find a wide variety of sources available from IBM to assist you Information IBM maintains pages on the web where you can get info...

Страница 18: ...e For the Storwize V7000 Unified the machine type is 2073 In the US and Canada hardware service and support can be extended to 24x7 on the same day The base warranty is 9x5 on the next business day Ge...

Страница 19: ...ring to get a professional answer The maintenance supplied with the system provides support when there is a problem with a hardware component or a fault in the system machine code At times you might n...

Страница 20: ...xx IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...

Страница 21: ...nstalling and configuring a Storwize V7000 Unified system 5 The Initial setup e Learning module is available on the IBM Storwize V7000 Unified Information Center Refer to Initial set up located under...

Страница 22: ..._ v License Function authorization document __ v IBM Storwize V7000 Unified Quick Installation Guide __ v Storwize V7000 Unified Problem Determination Guide __ v One USB flash drive also known as a fl...

Страница 23: ...he ports Step 2 Identifying the hardware components The following graphics and descriptions identify the various hardware components and port locations for the control enclosure expansion enclosure an...

Страница 24: ...y units for the control enclosure and expansion enclosure are not interchangeable v Two canisters are housed in the middle of the enclosure Each canister is known as a node canister The upper canister...

Страница 25: ...e connected first the use of port 2 is optional v 4 Serial attached SCSI SAS ports Each canister has two SAS ports The ports are side by side on the canister They are numbered 1 on the left and 2 on t...

Страница 26: ...e down Important The power supply units for the control enclosure and expansion enclosure are not interchangeable v Two canisters are housed in the middle of the enclosure Each canister is known as an...

Страница 27: ...ifies the various ports and hardware in the front of the file module Each enclosure takes up the full 2U height in the rack See the Storwize V7000 Unified Problem Determination Guide PDF on the CD for...

Страница 28: ...2 connected to the control enclosure v 3 Ethernet port 8 v 4 Ethernet port 9 v 5 Ethernet port 10 v 6 Power supplies 1 is lower 2 is upper v 7 Ethernet port 1 connected to the other file module v 8 Et...

Страница 29: ...browser from the following website http publib boulder ibm com infocenter storwize unified_ic topic com ibm storwize v7000 unified 130 doc svc_configuringbrowser_1obg15 html Step 4 Reviewing enclosur...

Страница 30: ...losure For each additional expansion enclosure that you add alternately add it below or above the control enclosure v Position the enclosures in the rack so that you can easily view them and access th...

Страница 31: ...stem configuration and initialization You need to have some information ready before you begin the initialization of your system such as the IP addresses Refer to Information required before initializ...

Страница 32: ...has the same network gateway IP address set and the same subnet mask set as the Unified system will use 2 Ping the network Gateway IP address that the Storwize V7000 Unified system will use This shoul...

Страница 33: ...initial setup may appear to be successful and the system could work for some time before random problems start to happen which are very hard to troubleshoot If you need to change an IP address after i...

Страница 34: ...ation Field Value Notes Storwize V7000 primary IP address Primary management IP address for the Storwize V7000 system such as 123 123 123 20 Storwize V7000 secondary IP address Optional secondary mana...

Страница 35: ...s assigned to file module 2 such as 123 123 123 12 Note The Storwize V7000 service IP addresses are not set by the USB Initialize or by the initial configuration done through the management GUI Refer...

Страница 36: ...thernet switch v F Client machine v G Client machine v H Fibre Channel switch v AA 1 Gbps Ethernet direct connection between the file modules v BB 10 Gbps Ethernet network v CC Fibre Channel network v...

Страница 37: ...re typically used in combination Example myfilesytem1 company com DNS servers Numerical address of user Domain Name Server for example 123 123 123 102 can be multiple server addresses DNS search domai...

Страница 38: ...me The name of your company Address This is the address where the machines are located Example Bldg 123 Room 456 789 N Data Center Rd City State Your Contact Phone Number This is the primary phone num...

Страница 39: ...34 224 443 Problem reporting server v4 www 945 ibm com 129 42 42 224 443 Problem reporting server v4 www ibm com 129 42 56 216 80 443 Service provider file CCF download www ibm com 129 42 58 216 80 44...

Страница 40: ...V7000 Unified system The authentication system may also be used to provide User ID mapping Several authentication methods are supported They are v Microsoft Active Directory with or without SUA SFU v...

Страница 41: ...and Windows clients access the same files using NFS and CIFS requires external user mapping using either Active Directory with SUA SFU or LDAP with Samba extensions Authentication Infrastructure Local...

Страница 42: ...irectory or PDC only One or more of these optional capabilities may be used to extend the capabilities of the authentication method selected previously If none of these options are needed then leave t...

Страница 43: ...isting Active Directory group with a valid UNIX GID assigned to it The SFU users must have the same UNIX Attribute primary group and Windows primary group The UNIX UID GID that are assigned to such us...

Страница 44: ...the LDAP group suffix to be used Bind Distinguished Name This is the bind distinguished name from the etc openldap slapd conf file on your LDAP server In the example following note 1 below the bind di...

Страница 45: ...gs allowing UNIX servers to access Network Attached Storage devices that use Microsoft Active Directory or PDC to authenticate users If you checked None in the Authentication Method field of Table 10...

Страница 46: ...o not have a mapping entry in the NIS Example ad_domain1 DENY_ACCESS v AUTO a new ID for the user is generated from the specific domain which does not have an entry in the NIS This ID is generated fro...

Страница 47: ...in the Options field of Table 10 on page 22 then check the Use ID Map field ID MAP USER RANGE If the Use ID Map field is blank leave this field blank If the Use ID Map field is checked AND at least on...

Страница 48: ...28 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...

Страница 49: ...block any air vents usually 15 cm 6 inch of space provides proper airflow v Do not leave open spaces above or below an installed control enclosure in the rack cabinet To help prevent damage to control...

Страница 50: ...lled on the sides of the enclosures The other set of rails must be installed in the rack cabinet The rails on the sides of the enclosures slide into the rails that are installed in the rack cabinet 2...

Страница 51: ...screw into the rack mounting hole 3 between the rail location pins 5 Tighten the screw to secure the rail to the rack 6 Working from the rear of the rack cabinet extend the rail that you secured to th...

Страница 52: ...ide 10 Repeat the steps to secure the opposite rail to the rack cabinet 11 Repeat the procedure for each additional enclosure Step 7 Installing the enclosures Install the enclosures making sure you fo...

Страница 53: ...cted to disconnect power during servicing v Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet Do not plug a power cord from a device installed in one...

Страница 54: ...installed b The rails are not designed to hold an enclosure that is partially inserted The enclosure must always be in a fully inserted position c Do not have more than one enclosure extended out of...

Страница 55: ...space provides proper airflow v Do not leave open spaces above or below an installed file module in the rack cabinet To help prevent damage to file module components always install a blank filler pane...

Страница 56: ...e of the file module These instructions are shown with the cable management arm mounted on the left side The installation instructions in this document can be reversed if you are installing the cable...

Страница 57: ...th either an R right or an L left Select one of the slide rails and pull the rear bracket all the way back If a thumbscrew is installed in the slide rail remove it Friction rail left Friction rail rig...

Страница 58: ...he rear of the slide rail in the selected unit on the rear of the rack Push the rails so that the pins go into the holes and slide the rails into the rack to lock the rear of the slide rails into the...

Страница 59: ...structions 1 Pull the slide rails forward 1 until they click two times into place Carefully lift the file module and tilt it into position over the slide rails so that the rear nail heads 2 on the dev...

Страница 60: ...k until it clicks into place 3 Insert both ends of the cable management support arm to the slide rail ifs00025 2 3 1 Figure 25 Install the file module on the slide rails ifs00026 2 1 Figure 26 Slide t...

Страница 61: ...h inside and outside of the slide rail Push the tabs until they snap into place 5 Make sure that the support rail is located between the 2 nail head features ifs00027 Figure 27 Install the cable manag...

Страница 62: ...loop fasteners Note Allow slack in all cables to avoid tension in the cables as the cable management arm moves 7 Insert the M6 screws to the rear of the slides Use a cable tie to secure the free end o...

Страница 63: ...to the expansion enclosures About this task This task applies if you are installing one or more expansion enclosures Note The enclosure terminology that is used in this topic is described fully in Ste...

Страница 64: ...cable is successfully inserted Note If you make a mistake during cabling and must unplug a SAS cable pull the blue tag to release the cable The following table refers to Figure 33 on page 45 Table 14...

Страница 65: ...nnect all supply power for complete isolation Disconnect all supply power for complete isolation Disconnect all supply power for complete isolation Disconnect all supply power for complete isolation C...

Страница 66: ...enclosure a Port 1 1 of the upper canister control enclosure attaches to Port 1 2 of the upper canister expansion enclosure 1 b Port 1 3 of the lower canister control enclosure attaches to Port 1 4 o...

Страница 67: ...nverted from the port locations on the upper canister Port 1 on the lower canister is opposite port 1 on the upper canister Note The connecting sequence from port 2 of the node canister is called chai...

Страница 68: ...on expansion enclosure 2 a Add the enclosures alternately to chain 1 and then chain 2 b Use port 2 on the canisters that are already connected to attach to port 1 on the canisters of the enclosures th...

Страница 69: ...ules and two are connected to the SAN v 2 USB ports Each node canister has two USB ports The ports are side by side on the canister and are numbered 1 on the left and 2 on the right One port is used d...

Страница 70: ...rol enclosure must be able to communicate over the network with the file modules 3 right port Figure 37 on page 49 Built in Ethernet port 2 1 Gbps external network connection No Optional management an...

Страница 71: ...file module 6 Ethernet port 2 From the internal IP address range Connect to the other file module 7 Ethernet port 3 File module service and system management IP address Connect to a switch for public...

Страница 72: ...cable management arms and secure any excess using the cable retention features of the rack File module management and public ports v Connect an Ethernet cable from Ethernet port 3 on the first file m...

Страница 73: ...e After the blue indicator light appears when the file modules are powered on the amber LED with the number 8 stamped on the metal next to each Fibre Channel port should be lit to show that the link s...

Страница 74: ...ts 3 and 4 Step 13 Connecting the power cords Connect the power cords to the power supply units About this task Control enclosure Two power supply units are located in each enclosure Ensure that the p...

Страница 75: ...t towards the cable plug in 4 Attach a power cord to each of the two power supply units in each enclosure Ensure that cables are installed in an orderly way to reduce the risk of cable damage when rep...

Страница 76: ...through the Cable Management Arms 2 Repeat the previous step for the other file module 3 Secure any excess cable length using the cable retention features of the rack Step 14 Powering the system on an...

Страница 77: ...the power supply units located at the front of the expansion enclosure Figure 45 on page 58 shows the location of the LEDs on the power supply units located at the rear of the expansion enclosure The...

Страница 78: ...are on If no cable is plugged into the port or if the canister at either end of the cable is not yet fully started the LEDs are not on Power supply unit expansion enclosure The reference to the left a...

Страница 79: ...d Figure 46 shows the location of the LEDs on the power supply units in the rear of the control enclosure Table 20 LED status when control enclosure is powered on Hardware component LED name If power...

Страница 80: ...de canister is an active member of a clustered system The LED is flashing if the node canister is in service or candidate state If the LED is off the node canister might still be booting up Wait up to...

Страница 81: ...xample it can respond to a remote request to turn on the file module While the file module remains connected to power one or more fans might continue to run To remove all power from the file module yo...

Страница 82: ...62 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...

Страница 83: ...dy in use by some other system on the network apart from the gateway IP address Refer to Checking that IP addresses are not already in use on page 12 If you provide an IP address that is already in us...

Страница 84: ...Problem Determination Guide PDF on the DVD d Proceed to Step 16 Initialize the Storwize V7000 on page 65 WARNING If InitTool exe does not ask you for the management IP file module 1 IP and file modul...

Страница 85: ...lid green and the status LED is blinking green on each of the node canisters 2 Insert the USB flash drive into either USB connector located at the back of the Storwize V7000 control enclosure on the u...

Страница 86: ...cludes integrated help If you move your cursor over certain terms or objects a question mark appears Moving your cursor over the question mark displays a description of that term In other areas of the...

Страница 87: ...drop down menu specifies the network interface for example ethX1 to use for attaching the network Step 19 Change default passwords Use the ssh connection to set the superuser root and admin passwords...

Страница 88: ...primarily for help desks and support engineers to diagnose and fix problems without the need of any external dependencies Assist On Site is based on the IBM Tivoli Remote Control technology About thi...

Страница 89: ...Notifications About this task Register for My Notifications to establish quick links to important information and to receive daily or weekly notifications of the following product specific information...

Страница 90: ...ation v The Storwize V7000 control enclosure has the ability send an inventory information email to IBM at regular intervals Refer to Setting up email event notifications and inventory reports using t...

Страница 91: ...v Industry standard devices ports and connectors v You can attach alternative input and output devices The Storwize V7000 Unified Information Center and its related publications are accessibility ena...

Страница 92: ...72 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...

Страница 93: ...send inquiries in writing to Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan Ltd 19 21 Nihonbashi Hakozakicho Chuo ku Tokyo 103 8510 Japan The following paragraph does no...

Страница 94: ...urements may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment Information concerning non IBM pr...

Страница 95: ...dobe Systems Incorporated in the United States and or other countries Linux and the Linux logo is a registered trademark of Linus Torvalds in the United States other countries or both Microsoft Window...

Страница 96: ...s in conformity with the protection requirements of European Union EU Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility IBM...

Страница 97: ...zu ergreifen und daf r aufzukommen Deutschland Einhaltung des Gesetzes ber die elektromagnetische Vertr glichkeit von Ger ten Dieses Produkt entspricht dem Gesetz ber die elektromagnetische Vertr gli...

Страница 98: ...Tel 0800 016 888 Japan VCCI Council Class A statement This explains the Japan Voluntary Control Council for Interference VCCI statement Japan Electronics and Information Technology Industries Associa...

Страница 99: ...Korean Communications Commission Class A Statement This explains the Korean Communications Commission KCC statement Russia Electromagnetic Interference Class A Statement This statement explains the Ru...

Страница 100: ...80 IBM Storwize V7000 Unified Model 2073 720 Quick Installation Guide...

Страница 101: ......

Страница 102: ...Part Number 00AR284 Printed in USA GC27 5945 01 1P P N 00AR284...

Отзывы: