Configure the Storwize V7000 Unified software, NAS file storage (total time 40
minutes)
1.
Select
NAS File Services
, enter NTP and DNS
information.
2.
Select a user authentication method, consult the
Information Center to choose an appropriate
authentication method, if unsure choose
Local
Authentication
. This authentication is used for the NAS
connectivity only.
The system supports the following authentication
services:
v
Lightweight Directory Access Protocol (LDAP)
v
SAMBA Primary Domain Controller (PDC)
v
Active Directory Server (ADS)
v
Active Directory (AD) with Microsoft Windows
Services for UNIX (SFU)
v
Network Information Service (NIS)
v
Local Authentication
3.
From
Public Networks
, select
New Network
and
enter the details collected earlier.
4.
The system is now ready for file services. It reboots
both Storwize V7000 Unified file modules This can take
up to 30 minutes, during that time the GUI is
inaccessible.
Change the default login details and check the health status of the system
Note:
The following section requires an SSH client, an example of this is Putty for Windows.
First ssh to the Storwize V7000 Unified management IP
using port 22. Log in with user ID admin and password
admin.
v
Issue command svctask chuser -password
superuser_password superuser, where
superuser_password is the new superuser password
that you want to use. The password must be a
minimum of 6 characters.
v
Change the default root password for the management
node. Issue command chrootpwd and follow the
prompts to change the password. The password must
be a minimum of 5 characters.
v
Change the default admin password for the
management node. Issue command chuser admin -p
new_password where new_password is the new
password that you want to use. The password must be
a minimum of 8 characters.
Check the system health by sshing to the Storwize V7000
Unified management IP using port 22. Log in with user
ID admin.
v
Issue the command lshealth, all statuses must report as
OK
v
Issue the command chkauth, it must report successful
v
Issue the command chkauth –ping, it must report
successful (if not using local auth)
4
IBM Storwize V7000 Unified: Model 2073-720 Quick Start Guide
Содержание Storwize V7000 Unified2073-720
Страница 1: ...IBM Storwize V7000 Unified Model 2073 720 Quick Start Guide GI13 2867 00...
Страница 2: ......
Страница 8: ...6 IBM Storwize V7000 Unified Model 2073 720 Quick Start Guide...
Страница 9: ......
Страница 10: ...Part Number 00AR299 Printed in USA GI13 2867 00 1P P N 00AR299...