IBM Storwize V7000 Gen2 Скачать руководство пользователя страница 8

viii

Storwize V7000 Gen2: Quick Installation Guide

Содержание Storwize V7000 Gen2

Страница 1: ...IBM Storwize V7000 Gen2 Quick Installation Guide GC27 6500 02...

Страница 2: ...Safety and environmental notices on page ix v The information in the IBM Environmental Notices and User Guide provided on a DVD This edition applies to IBM Storwize V7000 and is valid until replaced b...

Страница 3: ...4 port host interface card 25 Connecting Fibre Channel cables to an 8 Gbps Fibre Channel 4 port host interface card 26 Powering on the system 27 Chapter 3 Configuring the system 29 Checking your web...

Страница 4: ...iv Storwize V7000 Gen2 Quick Installation Guide...

Страница 5: ...spring 16 14 Hole locations in the front of the rack 17 15 Opening the hinge brackets 18 16 Closing the hinge brackets 18 17 Removing enclosure end caps 19 18 Inserting the enclosure 20 19 Reinstalli...

Страница 6: ...vi Storwize V7000 Gen2 Quick Installation Guide...

Страница 7: ...websites xxi 4 IBM websites for help services and information xxiii 5 Steps for different installation scenarios 2 6 Storwize V7000 model numbers 5 7 Selecting bracket pins for your rack 13 8 Selecti...

Страница 8: ...viii Storwize V7000 Gen2 Quick Installation Guide...

Страница 9: ...r publications that were provided with the Storwize V7000 hardware 3 Find the matching identification number in the IBM Storwize V7000 Safety Notices Then review the topics concerning the safety notic...

Страница 10: ...ated text for a caution or danger notice 1 In the product documentation look for the identification number at the end of each caution notice or each danger notice In the following examples the numbers...

Страница 11: ...n any side front or back of a unit used for air flow through the unit v Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does...

Страница 12: ...our rack cabinet for the weight of a loaded rack cabinet v Verify that all door openings are at least 760 x 230 mm 30 x 80 in v Ensure that all devices shelves drawers doors and cables are secure v En...

Страница 13: ...ly the same model rack should be coupled together with another same model rack R009 Danger notices for Storwize V7000 Ensure that you are familiar with the danger notices for Storwize V7000 Use the re...

Страница 14: ...to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems network...

Страница 15: ...re to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing v Connect all devices installed in a rack cabinet to power devices installed in the same rack ca...

Страница 16: ...l safety When you service the Storwize V7000 follow general safety guidelines Use the following general rules to ensure safety to yourself and others v Observe good housekeeping in the area where the...

Страница 17: ...or frame v Do not touch solder joints pins or exposed printed circuitry v Do not leave the device where others can handle and possibly damage the device v While the device is still in its antistatic...

Страница 18: ...To view a PDF file you need Adobe Reader You can download it at no charge from the Adobe web site get adobe com reader xviii Storwize V7000 Gen2 Quick Installation Guide...

Страница 19: ...bsite publib boulder ibm com infocenter storwize ic index jsp Storwize V7000 library Unless otherwise noted the publications in the Storwize V7000 library are available in Adobe portable document form...

Страница 20: ...ribes verifying your order becoming familiar with the hardware components and meeting environmental requirements The second chapter describes installing the hardware and attaching data cables and powe...

Страница 21: ...ranty 2145 and 2076 This multilingual document provides information about the IBM warranty for machine types 2145 and 2076 Part number 4377322 IBM License Agreement for Machine Code This multilingual...

Страница 22: ...d accessibility information To view a PDF file you need Adobe Reader which can be downloaded from the Adobe website www adobe com support downloads main html How to order IBM publications The IBM Publ...

Страница 23: ...wide contacts http www ibm com planetwide Support for Storwize V7000 2076 www ibm com storage support storwize v7000 Support for IBM System Storage and IBM TotalStorage products www ibm com storage su...

Страница 24: ...ort include v Check all cables to make sure that they are connected v Check all power switches to make sure that the system and optional devices are turned on v Use the troubleshooting information in...

Страница 25: ...a hardware component or a fault in the system machine code At times you might need expert advice about using a function provided by the system or about how to configure the system Purchasing the IBM S...

Страница 26: ...xxvi Storwize V7000 Gen2 Quick Installation Guide...

Страница 27: ...re supplying are available for installation Installation scenarios Depending on your order this documentation steps you through setting up your system for the following scenarios v Setting up a new sy...

Страница 28: ...closure on page 11 Installing support rails for expansion enclosures on page 15 Installing support rails for expansion enclosures on page 151 Installing support rails for the control enclosure on page...

Страница 29: ...that can be potentially hazardous to you Before installing read and understand the following caution and danger statements v Use safe practices when lifting The fully populated enclosure weighs about...

Страница 30: ...onnect or disconnect signal cables Never turn on any equipment when there is evidence of fire water or structural damage Disconnect the attached power cords telecommunications systems networks and mod...

Страница 31: ...ives __ v Rack mounting hardware kit including __ Two rails right and left assembly __ Two rail springs __ Two sets of rail mounting screws and alternative rail mounting pins large and small for non I...

Страница 32: ...e ports v 1 USB ports Each canister has two USB ports v 2 Ethernet ports Each canister has four 1 Gbps Ethernet ports Port 1 Must be connected for system management Can optionally be used for iSCSI ho...

Страница 33: ...ure support rail the top edge curves over to capture the top edge of an inserted control enclosure This prevents the installed control enclosure bouncing when the rack is subjected to quake or vibrati...

Страница 34: ...n expansion enclosure v The ledge on the inside of each rail supports the entire length of an expansion enclosure v The expansion enclosure support rails capture the left and right rear edges of an in...

Страница 35: ...see the Storwize V7000 physical installation planning topic in the Storwize V7000 Information Center Reviewing enclosure location guidelines Before installing the enclosures you must be familiar with...

Страница 36: ...them evenly into rack space above and below the control enclosure that they will connect to without leaving gaps between the enclosures This aids cabling and serviceability v Leave space in the rack...

Страница 37: ...ore you install the control enclosure you must first install the support rails for it Procedure To install the support rails for the control enclosure complete the following steps 1 Locate the control...

Страница 38: ...dard rack units 2U of space in the rack into which you want to install the support rails Figure 9 on page 13 shows two rack units with the front mounting holes identified fab10050 Figure 8 Installing...

Страница 39: ...propriate for the mounting holes in your rack see Table 7 Table 7 Selecting bracket pins for your rack Mounting holes Bracket pins Round unthreaded Use the preinstalled medium pins Round threaded Unsc...

Страница 40: ...the front of the rail press the two bracket pins into the holes in the rack flanges 10 Close the front hinge bracket to secure the rail to the rack cabinet flange See Figure 11 11 Secure the rear of...

Страница 41: ...at must be installed in the rack cabinet 2 Install a spring on each rail a Extend the rail to its full length b Push one looped end of a spring over one stud on the inside of the rail See Figure 13 on...

Страница 42: ...ard rack units 2U of space in the rack into which you want to install the support rails Figure 14 on page 17 shows two rack units with the front mounting holes identified fab10052 Figure 13 Installing...

Страница 43: ...ropriate for the mounting holes in your rack see Table 8 Table 8 Selecting bracket pins for your rack Mounting holes Bracket pins Round unthreaded Use the preinstalled medium pins Round threaded Unscr...

Страница 44: ...the front of the rail press the two bracket pins into the holes in the rack flanges 10 Close the front hinge bracket to secure the rail to the rack cabinet flange See Figure 16 11 Secure the rear of t...

Страница 45: ...rovided with the enclosure CAUTION v To lift a control enclosure with drives installed requires at least three people v Install a control enclosure only onto the control enclosure rails supplied with...

Страница 46: ...n the rack mounting screw holes See Figure 18 and Figure 19 on page 21 5 Reinstall the left and right end caps See Figure 19 on page 21 The left end cap has indicator windows that align with the statu...

Страница 47: ...st of guidelines to ensure that your configuration is valid Do not begin connecting the cables until you have read SAS cabling guidelines on page 23 Note When connecting SAS cables between enclosures...

Страница 48: ...to SAS port 1 of the right expansion canister in the second expansion enclosure 3 If additional expansion enclosures are installed connect each one to the previous expansion enclosure in a chain using...

Страница 49: ...erted correctly the green link LEDs next to the connected SAS ports are lit Guidelines Be aware of the following guidelines when you begin to attach the cables to the SAS ports v No more than ten expa...

Страница 50: ...t or optionally present on the rear of each node canister Ports 1 and 2 provide access to system management facilities Ports 1 2 and 3 on the rear of each canister can also provide iSCSI connectivity...

Страница 51: ...additional iSCSI connectivity to the system Note Do not connect the Ethernet technician port labeled T to a network switch The technician port must only be directly connected to a personal computer w...

Страница 52: ...enter for instructions on determining the number of cables required Note Both canisters must have the same number of cables connected Figure 25 shows an example configuration with two Fibre Channel ca...

Страница 53: ...panel v Filler plates must be installed in all empty host interface card slots Open bays or slots disrupt the internal air flow causing the drives to receive insufficient cooling Procedure To power on...

Страница 54: ...itches ensure that they are turned on The enclosure does not have power switches Note Each enclosure has two power supply units To provide power failure redundancy connect the two power cords to separ...

Страница 55: ...UI To access the management GUI you must ensure that your web browser is supported and has the appropriate settings enabled Before you begin The management GUI supports the following web browsers v Mo...

Страница 56: ...k Add e Verify that the correct web address was added to the Trusted sites dialog f Click Close on the Trusted sites dialog g Click OK h Refresh your browser For Google Chrome a On the menu bar in the...

Страница 57: ...ct the Advanced tab d Scroll to the Security section e Check the Use TLS 1 1 and Use TLS 1 2 checkboxes Note IE 11 and later enable TLS 1 1 1 2 by default User name and password for system initializat...

Страница 58: ...dress 192 168 0 2 mask to 255 255 255 0 gateway to 192 168 0 1 and DNS to 192 168 0 1 5 After the Ethernet port of the personal computer is connected open a supported browser and browse to address htt...

Страница 59: ...n the SAN About this task The management GUI requires a supported web browser see Checking your web browser settings for the management GUI on page 29 Note When adding a control enclosure do not use t...

Страница 60: ...7 On the System page select Actions Add Enclosures 8 Continue to follow the on screen instructions 34 Storwize V7000 Gen2 Quick Installation Guide...

Страница 61: ...ices ports and connectors The Storwize V7000 Information Center and its related publications are accessibility enabled The accessibility features of the Information Center are described in Viewing inf...

Страница 62: ...36 Storwize V7000 Gen2 Quick Installation Guide...

Страница 63: ...mited Warranty is available in both hardcopy format and in the Storwize V7000 information center The Statement of Limited Warranty is shipped in hardcopy form with your product It can also be ordered...

Страница 64: ...38 Storwize V7000 Gen2 Quick Installation Guide...

Страница 65: ...send inquiries in writing to Intellectual Property Licensing Legal and Intellectual Property Law IBM Japan Ltd 19 21 Nihonbashi Hakozakicho Chuo ku Tokyo 103 8510 Japan The following paragraph does no...

Страница 66: ...e some measurements may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment Information concerning...

Страница 67: ...trademarks and logos are trademarks or registered trademarks of Oracle and or its affiliates Linux and the Linux logo is a registered trademark of Linus Torvalds in the United States other countries o...

Страница 68: ...ustralia and New Zealand Class A Statement Attention This is a Class A product In a domestic environment this product might cause radio interference in which case the user might be required to take ad...

Страница 69: ...inrichtung kann im Wohnbereich Funk St rungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Mabnahmen zu ergreifen und daf r aufzukommen Deutschland Einhaltung des Gesetzes...

Страница 70: ...tact Information IBM Taiwan Corporation 3F No 7 Song Ren Rd Taipei Taiwan Tel 0800 016 888 Japan VCCI Council Class A statement This explains the Japan Voluntary Control Council for Interference VCCI...

Страница 71: ...ommunications Commission Class A Statement This explains the Korean Communications Commission KCC statement Russia Electromagnetic Interference Class A Statement This statement explains the Russia Ele...

Страница 72: ...46 Storwize V7000 Gen2 Quick Installation Guide...

Страница 73: ...onformance statement 42 expansion canister data ports 8 LEDs 27 expansion enclosure adding to an existing system 33 attachment cables 21 23 installing 19 location guidelines 10 power cords 27 rails 15...

Страница 74: ...send a comment xxiii shortcut keys keyboard 35 Statement of Limited Warranty Where to find the 37 static sensitive devices xvii Storwize V7000 safety notices x xiii Storwize V7000 library related pub...

Страница 75: ......

Страница 76: ...Part Number 00RY225 Printed in USA GC27 6500 02 1P P N 00RY225...

Отзывы: