Figure 97. Removing the expansion canister
6. Carefully pull the expansion canister out of the chassis and place it on a safe, level surface.
Replace the expansion canister
7. To reinstall an expansion canister, or replace it with one from FRU stock, follow the procedure in
“Installing or replacing an expansion canister: 2077-92F ” on page 48.
Removing a fan module: 2077-92F
You can remove a faulty fan module from a 2077-92F expansion enclosure.
Before you begin
Important: You can remove a fan module without powering off the expansion enclosure. However, to
maintain operating temperature, do not remove more than one fan module at a time.
• Remove a faulty fan module only when its replacement is ready to be installed.
• Do not remove a fan module from an operational enclosure for more than approximately 10 minutes.
The reduction in airflow through the enclosure might cause the enclosure or its components to shut
down to protect from overheating.
About this task
Note: If you plan to remove the expansion enclosure from the rack, you must remove all of the fan
modules.
Procedure
1. Identify the fan module to be replaced. When lit, the amber LED on the front of the fan module (
1
in
Figure 98 on page 95) identifies a fault.
94 Storwize V5000 Gen2: Quick Installation Guide
Содержание Storwize V5000 Gen2
Страница 1: ...IBM Storwize V5000 Gen2 Quick Installation Guide IBM...
Страница 5: ...Index 149 v...
Страница 6: ...vi...
Страница 156: ...130 Storwize V5000 Gen2 Quick Installation Guide...
Страница 164: ...138 Storwize V5000 Gen2 Quick Installation Guide...
Страница 166: ...140 Storwize V5000 Gen2 Quick Installation Guide...
Страница 168: ...142 Storwize V5000 Gen2 Quick Installation Guide...
Страница 177: ......
Страница 178: ...IBM...