Connecting Ethernet cables for system management
To provide system management connectivity, you must connect Ethernet cables to
Ethernet port 1 of each node canister in the control enclosure. This connection can
optionally also be used for iSCSI host connection. Ethernet port 2 can optionally be
connected to provide a second system management address, a second iSCSI host
connection, or both.
About this task
Procedure
To install the cables, complete the following steps.
1.
Connect Ethernet port 1 on each node canister to the same Ethernet switch, as
shown in Figure 27.
2.
Optionally, connect Ethernet port 2 on each node canister to the same Ethernet
switch. (Figure 27 shows these optional cables in a lighter color.)
Connecting Ethernet cables to 1 Gbps iSCSI 4-port host interface
cards
If you installed 1 Gbps iSCSI 4-port host interface cards, you must connect
Ethernet cables to them.
About this task
The Ethernet port numbering on the host interface card starts at 3, because
Ethernet ports one and two are built into the canister.
Note:
The Ethernet cables are connected in pairs. Both canisters must have the
same number of cables connected.
Procedure
To install the cables, complete the following steps.
1.
Identify the correct pair of Ethernet cables for the Ethernet ports labeled 3 in
the left canister and the right canister.
2.
Connect the appropriate cable to each port.
1
2
3
4
6
1
2
1
2
OK
IN
1
2
3
4
6
1
2
1
2
OK
IN
v3500001
Figure 27. Connecting the Ethernet cables
Chapter 2. Installing the hardware
37
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Содержание Storwize V3700
Страница 1: ...IBM Storwize V3700 Quick Installation Guide GC27 4219 01...
Страница 4: ...iv Storwize V3700 Quick Installation Guide...
Страница 6: ...vi Storwize V3700 Quick Installation Guide...
Страница 8: ...viii Storwize V3700 Quick Installation Guide...
Страница 14: ...xiv Storwize V3700 Quick Installation Guide...
Страница 30: ...10 Storwize V3700 Quick Installation Guide...
Страница 64: ...44 Storwize V3700 Quick Installation Guide...
Страница 78: ...f2c00790 58 Storwize V3700 Quick Installation Guide...
Страница 81: ......
Страница 82: ...Part Number 00AR171 Printed in USA GC27 4219 01 1P P N 00AR171...