Glossary
A
array.
Two or more physical drives combined for
increased capacity, speed, or fault tolerance. Once
created, an array is configured as one or more logical
drives. The operating system in the server recognizes a
logical drive as a single drive.
auto-synchronization.
Synchronization on RAID
level-5, level-5E, and level-50 drives that is
automatically initiated when logical drives are created.
This type of synchronization works in the background.
B
battery-backup cache.
Buffer storage that protects
data during write-back operations; in the event of a
power failure, it preserves the data in the controller
cache.
BIOS-compatibility mapping.
A ServeRAID controller
setting with two options:
Limited
and
Extended
. The
default option is
Extended
.
BIOS-compatibility mapping—Extended.
An option
of BIOS compatibility mapping. When the BIOS
compatibility mapping is set to
Extended
, the
ServeRAID BIOS is aware that the operating system
supports 8 GB or smaller physical drives.
BIOS-compatibility mapping—Limited.
An option of
BIOS compatibility mapping. When the BIOS
compatibility mapping is set to
Limited
, the ServeRAID
BIOS is aware that the operating system supports 2 GB
or smaller physical drives. This enables the user to
migrate data from older PCI or Micro Channel
®
adapters.
block.
A data unit created when data is striped across
physical drives.
blocked.
A logical-drive state in which the data in a
RAID level-0 logical drive might be damaged and will
need to be restored. After an array fails and a rebuild
operation is initiated, the ServeRAID controller sets
RAID level-0 logical drives to the blocked state.
C
cluster.
In ServeRAID technology, two independent
computer systems organized into a network for the
purpose of sharing resources and communicating with
each other. A cluster provides fault-tolerance at the
server level.
compression.
The process by which a RAID level-5E
logical drive utilizes the distributed spare drive in the
event of a physical drive failure. After the data is
reconstructed, the original array undergoes compression
and the distributed spare drive becomes part of the new
array.
controller.
A device that coordinates and controls the
operation of one or more input/output devices, such as
workstations, and synchronizes the operation of such
devices with the operation of the system as a whole.
controller names.
In a cluster or failover pair, the
unique names that identify the members of the pair to
one another.
critical.
The state of a RAID level-1, level-1E, level-5,
level-5E, level-10, level-1E0, or level-50 logical drive
that contains a defunct drive.
D
data mirroring.
A technique that creates a single
logical drive from two physical drives. All data written to
the logical drive is written to both physical drives,
creating a pair of physical drives containing exactly the
same data.
data scrubbing.
A feature that provides automatic,
continuous synchronization during system use. This
features works in the background, and ensures that the
redundant data and/or parity is correct.
data striping.
A technique that divides a logical drive
into data blocks, called stripes, which are then
distributed over the physical drives. The layout is such
that a sequential read of data on the logical drive results
in parallel reads to each of the physical drives, resulting
in improved performance.
decompression.
The process by which a compressed
array returns to its original striping scheme, after a
failed drive is replaced in a RAID level-5E logical drive.
Contrast with compression.
defunct.
A physical-drive state in which the
ServeRAID controller cannot communicate properly with
the drive.
distributed spare drive.
In RAID level-5E, the logical
drive designated as a spare drive. Because this spare
drive is spread over several physical drives, it is
described as distributed.
E
enclosure.
A storage expansion unit, such as the
Netfinity
®
EXP300, that contains SCSI disk drives.
© Copyright IBM Corp. 2002
199
Содержание ServeRAID
Страница 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Страница 10: ...x IBM ServeRAID User s Reference Version 5 10...
Страница 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Страница 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Страница 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Страница 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Страница 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Страница 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Страница 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Страница 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Страница 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Страница 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Страница 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Страница 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Страница 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Страница 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Страница 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Страница 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Страница 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Страница 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Страница 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Страница 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Страница 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Страница 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Страница 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Страница 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Страница 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Страница 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Страница 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Страница 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Страница 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Страница 225: ......
Страница 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...