7.
Press
and
release
the
up
or
down
button
until
the
Ethernet
option
is
shown
on
the
front
panel
display.
The
second
line
of
the
front-panel
display
in
shows
the
message
Inactive
.
This
message
shows
that,
although
an
Ethernet
connection
is
available,
it
cannot
yet
be
used.
8.
Press
and
release
the
up
or
down
button
until
the
FC
Port-1
option
shows
in
the
display.
9.
Check
whether
the
second
line
of
the
front-panel
display
shows
the
message
Active
.
If
Active
is
not
shown
on
the
second
line,
go
to
the
fibre-channel
MAP
to
repair
the
fault.
10.
If
you
are
installing
a
SAN
Volume
Controller
2145-4F2
or
a
SAN
Volume
Controller
2145-8F2,
go
to
step
If
you
are
installing
a
SAN
Volume
Controller
2145-8F4,
go
to
step
11.
Press
and
hold
the
down
button.
12.
Press
and
release
the
select
button.
13.
Release
the
down
button.
The
operational
speed
of
the
fibre-channel
link
is
displayed.
Use
the
cable
connection
table
that
is
provided
by
the
customer
to
verify
that
the
fibre-channel
link
is
operating
at
the
expected
speed.
If
the
operational
speed
does
not
match
the
expected
speed,
go
to
the
fibre-channel
MAP
to
repair
the
fault.
14.
Press
the
select
button
to
return
to
the
fibre-channel
status
display.
15.
Press
the
right
button
to
display
each
port
in
turn
and
repeat
the
above
speed
check.
Go
to
step
16.
Press
and
release
the
left
or
right
button
to
display
the
other
port
options.
Check
whether
for
each
port,
the
second
line
of
the
front-panel
display
shows
the
message
Active
.
If
Active
is
not
shown
for
any
port,
go
to
the
fibre-channel
MAP
to
repair
the
fault.
17.
If
the
configuration
data
table
provided
by
the
user
indicates
that
the
SAN
Volume
Controller
nodes
are
to
be
operated
at
1
Gbps,
follow
these
steps:
a.
Press
and
hold
the
down
button.
b.
Press
and
release
the
select
button.
c.
Release
the
down
button.
The
second
line
of
the
front-panel
display
shows
the
current
fibre-channel
speed
setting
of
the
node.
Press
the
up
or
down
button
until
1
Gbps
is
displayed
and
then
press
the
select
button.
This
changes
the
fibre-channel
speed
for
all
ports
on
this
node
to
1
Gbps.
18.
If
you
want
to
select
a
language
other
than
English,
perform
the
following
steps:
a.
Press
the
up
or
down
button
until
Select
Language?
is
displayed.
N o d e :
x x x x x x
Figure
54.
Node
number
E t h e r n e t :
I n a c t i v e
Figure
55.
Ethernet
mode
Chapter
4.
Installing
the
UPS,
the
master
console,
and
the
SAN
Volume
Controller
77
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Содержание SAN Volume Controller 2145-8F4
Страница 1: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 2: ......
Страница 3: ...IBM System Storage SAN Volume Controller Installation Guide V ersion 4 1 0 GC26 7900 00...
Страница 8: ...vi IBM System Storage SAN Volume Controller Installation Guide...
Страница 74: ...44 IBM System Storage SAN Volume Controller Installation Guide...
Страница 78: ...48 IBM System Storage SAN Volume Controller Installation Guide...
Страница 120: ...90 IBM System Storage SAN Volume Controller Installation Guide...
Страница 122: ...92 IBM System Storage SAN Volume Controller Installation Guide...
Страница 128: ...98 IBM System Storage SAN Volume Controller Installation Guide...
Страница 134: ...104 IBM System Storage SAN Volume Controller Installation Guide...
Страница 138: ...108 IBM System Storage SAN Volume Controller Installation Guide...
Страница 141: ......
Страница 142: ...Part Number 31P0797 Printed in USA GC26 7900 00 1P P N 31P0797...
Страница 143: ...Spine information IBM System Storage SAN Volume Controller Installation Guide Version 4 1 0...