displayed on the front panel. If the node number is not the same, contact the
IBM Support Center.
7.
Press and release the up button or down button until the
Node:
option is
displayed on the first line of the front-panel display. The second line of the
front-panel display in Figure 51 shows the message
Inactive
. This message
indicates that, although an Ethernet connection is available, it cannot yet be
used.
8.
Press and release the up button or down button until the
FC Port-1
option
shows in the display.
9.
Check whether the second line of the front-panel display shows the message
Active
. If
Active
is not shown on the second line, go to MAP 5600: Fibre
channel in the
IBM System Storage SAN Volume Controller Troubleshooting Guide
to repair the fault.
10.
If you are installing a SAN Volume Controller 2145-8F2 node, go to step 16. If
you are installing a SAN Volume Controller 2145-8F4 node, go to step 11.
11.
Press and hold the down button.
12.
Press and release the select button.
13.
Release the down button. The operational speed of the fibre-channel link is
displayed. Use the cable connection table that is provided by the customer to
verify that the fibre-channel link is operating at the expected speed. If the
operational speed does not match the expected speed, go to MAP 5600: Fibre
channel in the
IBM System Storage SAN Volume Controller Troubleshooting Guide
to repair the fault.
14.
Press the select button to return to the fibre-channel status display.
15.
Press the right button to display each port in turn and ensure that the port is
active and the speed is correct. Go to step 18 on page 53
16.
Press and release the left or right button to display the other port options.
Check whether for each port, the second line of the front-panel display shows
the message
Active
. If
Active
is not shown for any port, go to “MAP 5600:
Fibre channel” in the
IBM System Storage SAN Volume Controller Service Guide
to repair the fault.
17.
If the configuration data table provided by the user indicates that the SAN
Volume Controller nodes are to be operated at 1 Gbps, follow these steps:
a.
Press and hold the down button.
b.
Press and release the select button.
c.
Release the down button.
N o d e :
x x x x x x
Figure 50. Node number
E t h e r n e t :
I n a c t i v e
Figure 51. Ethernet mode
52
IBM System Storage SAN Volume Controller: Models 2145-8F2 and 2145-8F4 Hardware Installation Guide
Содержание SAN Volume Controller 2145-8F2
Страница 2: ......
Страница 8: ...vi IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 24: ...xxii IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 54: ...30 IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 78: ...54 IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 80: ...56 IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 88: ...64 IBM System Storage SAN Volume Controller Models 2145 8F2 and 2145 8F4 Hardware Installation Guide...
Страница 95: ......
Страница 96: ...Printed in USA GC27 2221 00...