6-6
Using the Intelligent Battery Backup Unit
6.1.2.3
Display BBU Capacity
Use the command in
to display the BBU capacity for the
selected controller(s).
Description
Displays complete information about the BBU status, such as the temperature and
voltage. The information displays in the following formats:
BBU Status for Adapter: xx
Battery Type: XXXXXX(string)
Voltage: xx mV
Current: xx mA
Temperature: xx C°
Firmware Status: xx
Battery state: xx
Gas Gauge Status:
Fully Discharged: Yes/No
Fully Charged: Yes/No
Discharging: Yes/No
Initialized: Yes/No
Remaining Time Alarm: Yes/No
Remaining Capacity Alarm: Yes/No
Discharge Terminated: Yes/No
Over Temperature: Yes/No
Charging Terminated: Yes/No
Over Charged: Yes/No
Additional status information displays differently for iBBU™ and BBU.
For iBBU:
Relative State of Charge: xx
Charger System State: xx
Charger System Ctrl: xx
Charging Current: xx mA
Absolute State of Charge: xx%
Max Error: xx%
For BBU:
Relative State of Charge: xx
Charger Status: xx
Remaining Capacity: xx mAh
Full Charge Capacity: mAh
isSOHGood: Yes/No
Table 6.2
Display BBU Status Information
Table 6.3
Display BBU Capacity Information
Convention
MegaCli -AdpBbuCmd -GetBbuCapacityInfo –aN|-a0,1,2|-aALL
Содержание Redbooks ServeRAID-MR10i
Страница 1: ...ServeRAID MR10i USER S GUIDE F e b r u a r y 2 0 0 9 IBM P N 46M1377...
Страница 12: ...xii Contents...
Страница 14: ...xiv Contents...
Страница 16: ...xvi Contents...
Страница 58: ...5 6 Installing the Intelligent Battery Backup Unit...
Страница 78: ...A 4 Notices...
Страница 84: ...B 6 Glossary of Terms and Abbreviations...
Страница 85: ......
Страница 86: ...4 6 M1 3 7 7...