IBM System x3550 M4
22
Supported environment:
Air temperature
z
Server on: 5 C to 40 C (41.0 F to 104 F); altitude: 0 to 915 m (3,000 ft) for 60W to 95W processors
z
models.
Server on: 10 C to 35 C (50.0 F to 95 F); altitude: 0 to 915 m (3,000 ft) for 115W to 135W
z
processors models.
Server off: 5 C to 45 C (41.0 F to 113 F)
z
Shipment: -40 C to +60 C (-40 F to 140 F)
z
Humidity
z
For 115W to 130W processors/135W processors models
z
Server on: 20% to 80%, maximum dew point 21 C, maximum rate of change 5 C/hr
z
Server off: 8% to 80%, maximum dew point 27 C
z
For 60W to 95W processors models
z
Server on: 8% to 85%, maximum dew point 24 C, maximum rate of change 5 C/hr
z
Server off: 8% to 80%, maximum dew point 27 C
z
Electrical
z
Models with 750 W power supplies:
z
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.9 A
z
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.5 A
z
Input kilovolt-amperes (kVA) (approximately):
z
Minimum configuration: 0.14 kVA
z
Maximum configuration: 0.9 kVA
z
Models with 550 W power supplies:
z
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
z
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
z
Input kilovolt-amperes (kVA) (approximately):
z
Minimum configuration: 0.12 kVA
z
Maximum configuration: 0.66 kVA
z
BTU output
z
Minimum configuration: 406 Btu/hr (119 watts)
z
Maximum configuration: 2900 Btu/hr (850 watts)
z
Noise level
z
6.5 bels (operating)
z
6.3 bels (idle)
z