Sample File modem_z0.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP Z0
#
# FUNCTIONS: Modem configuration file for some early Hayes* compatible modems.
#
This example uses the ATZ0 reset command to choose the factory defaults.
#
This setup is recommended for modems that will respond to the ATZ0 command
#
and which do not respond to the extended (&) commands.
Refer to your modem
#
manual.
#
# * Trademark of Hayes Microcomputer Products, Inc.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# If the modem has configuration switches, they should be set to the
# factory default settings.
ICDelay 1
DefaultTO 10
CallDelay 120
#
AT
Attention Code
,
Inserts delay in dialing commands
#
Z0
Reset. Restore Profile 0 Q0
Turn on responses
#
E0
Turn echo off
Q1
Turn off responses
#
V0
Use numeric responses
S0=0 Automatic answer inhibit
# +++
Escape to command mode
S0=2 Answer on second ring
#
H0
Hang-up
X0=0 Limit modem response codes
#
T =
Tone mode.
When used as T\r, it is a
#
no op to maintain program synchronization
#
when modem may/will echo the commands.
#
#
%N
Call-Out phone number
%P
Paging phone number
#
%S
Modem speed (available to users)
#
# Following are common responses from a wide range of modems:
# 16, 15, 12, 10, 5 and 1 are connection responses.
Add others as required.
# 7=busy; 6=no dial tone; 4=error; 3=no carrier; 2=ring; 0=OK
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout:
send "ATZ0Q0T\r"
# Reset modem. Select profile 0
ignore "0\r" or "OK\r\n" timeout 2
# Ignore modem response.
send "ATE0T\r"
# Initialize modem: Echo OFF,
expect "0\r" or "OK\r\n" timeout 2
#
Enable responses (Numeric),
send "ATQ0V0X0T\r"
#
Limit response codes.
expect "0\r" timeout 2
# Confirm commands successful.
send "ATS0=0\r"
# Set AutoAnswer OFF
expect "0\r" timeout 2
# Confirm command successful.
done
connect:
send "ATDT%N\r"
# Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.
expect "16\r" or "15\r" or "14\r" or "12\r" or "10\r" or "5\r" or "1\r" busy "7\r"
Appendix E. Modem Configurations
169
Содержание pSeries 615 Model 6C3
Страница 1: ...pSeries 615 Model 6C3 and Model 6E3 User s Guide SA38 0629 00 ERserver ...
Страница 2: ......
Страница 3: ...pSeries 615 Model 6C3 and Model 6E3 User s Guide SA38 0629 00 ERserver ...
Страница 14: ...xii pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 16: ...xiv pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 20: ...xviii pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 26: ...6 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 46: ...26 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 86: ...66 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 110: ...90 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 146: ...126 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 164: ...144 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 168: ...148 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 172: ...152 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 204: ...184 pSeries 610 Model 6C3 and Model 6E3 User s Guide ...
Страница 207: ......