A00-FF0 through A24-xxx SRNs
AIX might generate service request numbers (SRNs) from A00-FF0 to A24-xxx.
Note:
Some SRNs in this sequence might have 4 rather than 3 digits after the dash (–).
Table 26 shows the meaning of an
x
in any of the following SRNs, such as A01-00x.
Table 26. Meaning of the last character (x) after the hyphen
Number
Meaning
1
Replace all FRUs listed
2
Hot swap supported
4
Software might be the cause
8
Reserved
Table 27 describes each SRN and provides a recommended corrective action.
Table 27. A00-FF0 through A24-xxx SRNs
SRN
Description
FRU/action
A00-FF0
Error log analysis is unable to
determine the error. The error log
indicates the following physical FRU
locations as the probable causes.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A01-00x
Error log analysis indicates an error
detected by the microprocessor, but the
failure could not be isolated.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A01-01x
GCPU internal error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A01-02x
CPU internal cache or cache controller
error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A01-05x
System bus time-out error.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
Chapter 2. Diagnostics
157
Содержание PS700
Страница 1: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 2: ......
Страница 3: ...Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y GI11 9831 00 ...
Страница 244: ...232 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 281: ...d Click BladeCenter PS700 to display the list of downloadable files for the blade server Chapter 5 Configuring 269 ...
Страница 282: ...270 Power Systems Problem Determination and Service Guide for the IBM Power PS700 8406 70Y ...
Страница 293: ......
Страница 294: ... Printed in USA GI11 9831 00 ...