7.11 1055 Battery
Cover and Front Bezel (1005)
Power Supply (1045)
CAUTION:
The lithium battery presents a fire, explosion, or severe burn risk. Do
not recharge it, disassemble it, heat it above 100°C (212°F), incinerate
it, or expose its cell contents to water. Dispose of the battery as
required by local ordinances or regulations. When replacing the battery,
use only Part No. 33F8354. Use of another battery could result in
ignition or explosion of the battery. Replacement batteries can be
ordered from IBM or IBM Authorized Dealers.
Warning: The battery is located on the system board. Be careful when
removing or replacing the battery. If the battery clip is broken the
system board must be replaced.
Note: If the battery is removed, run the set configuration program from
the hard disk drive to reset the system-configuration information.
PICTURE 14
IBM PS/2 Model 95 XP 486 HMR
1055 Battery
¦ Copyright IBM Corp. 1990, 1991
7.11 - 1