- Insert your advanced diagnostics diskette.
- Press Ctrl+Alt+Del and check for the following responses:
1. One or two short beeps.
2. IBM logo screen appears.
DID YOU RECEIVE BOTH RESPONSES?
Yes No
¦ ¦
¦ +---+
¦ ¦011¦
¦ +---+
¦ Go to "Symptom-to-FRU Index" in topic 13.0.
¦
¦ If that does not correct the problem, go to "Undetermined Problem" in
¦ topic 2.0.
¦
¦
+---+
¦012¦
+---+
- Select Test the System.
- Select System Checkout.
If the system has incorrect keyboard responses, go to "Keyboard" in
topic 6.0.
If the printer has incorrect responses, go to "Printer" in
topic 7.0.
If the display has problems such as jittering, rolling, shifting, or
being out-of-focus, go to "Display" in topic 4.0.
IS THE LIST OF INSTALLED DEVICES CORRECT?
Yes No
¦ ¦
¦ +---+
¦ ¦013¦
¦ +---+
¦ Go to "Installed Devices List" in topic 5.0.
¦
¦ If that does not resolve the problem, continue with Step 015.
¦
¦
+---+
¦014¦
+---+
- Run the advanced diagnostic tests.
DID THE TESTS IDENTIFY A FAILURE?
Note: If the test stops and you cannot continue, replace the last device
tested.
Yes No
¦ ¦
¦ ¦
¦ +---+
¦ ¦015¦
¦ +---+
¦ Check the "Symptom-to-FRU Index" in topic 13.0 for any POST error or
¦ other error symptom you might have. If your error symptom is not
¦ listed, go to "Undetermined Problem" in topic 2.0.
¦
¦ If you cannot find a problem, it may be intermittent:
¦ Check for damaged cables and connectors.
¦ Reseat all adapters, drives, and modules.
¦ Check the system unit fan for proper operation.
¦ Start an error log and run the tests multiple times. (Use a
¦ DOS-formatted diskette.)
¦
+---+
¦016¦
+---+
Follow the instructions on the display.
If that does not correct the problem, go to "Symptom-to-FRU Index" in
topic 13.0.
--------------------------------------------------------------------------
IBM PS/2 Model 25 SX HMR
How to Disable the Power-on Password
¦ Copyright IBM Corp. 1992
1.3 - 2
Содержание PS/2 25 SX
Страница 26: ......
Страница 30: ... IBM PS 2 Model 25 SX HMR Symptom to FRU Index Copyright IBM Corp 1992 13 0 4 ...
Страница 34: ...15 0 System Overview PICTURE 7 IBM PS 2 Model 25 SX HMR System Overview Copyright IBM Corp 1992 15 0 1 ...
Страница 37: ...Printed in the United States of America IBM PS 2 Model 25 SX HMR Parts Catalog Copyright IBM Corp 1992 16 0 3 ...