Table 10. Sensor information, event description, and service action for the 5104-22C, 9006-12P,
9006-22C, or 9006-22P (continued)
Sensor name (Sensor ID)
Event description
Service action
Watchdog (0xFF)
• Timer Expired
• Reserved1
• Reserved2
• Reserved3
• Reserved4
No service action is required.
• Hard Reset
• Power Down
• Power Cycle
• Timer Interrupt
Search for serviceable SEL events
that have a time stamp close to
the time stamp of this SEL event.
If you found a serviceable SEL
event, perform the service action
that is indicated in this table for
the SEL event. If you cannot boot
the system to the Petitboot
menu, go to “Resolving a system
firmware boot failure” on page 5.
Isolation procedures
Use this information to isolate problems that might occur with your system.
EPUB_PRC_FIND_DECONFIGURE_PART isolation procedure
A part vital to the system has been deconfigured.
Procedure
1. Use the
ipmitool
command to examine system event logs (SELs).
• To list SELs by using an in-band network, use the following command:
ipmitool sel elist
• To list SELs remotely over the LAN, use the following command:
ipmitool -I lanplus -U <username> -P <password> -H <BMC IP addres or BMC hostname> sel
elist
2. Identify all SELs with the value
OEM record df
and Correctable Machine Check Error or Transition
to Non-recoverable in the description. Did you find one or more SELs with the value
OEM record df
and Correctable Machine Check Error or Transition to Non-recoverable in the description?
If
Then
Yes:
Continue with the next step.
No:
Go to “Contacting IBM service and support” on page 61. This ends the procedure.
3. For each of the SELs that you identified in step “2” on page 49, determine the sensor name that is
associated with each SEL. Replace the following items, one at a time until the problem is resolved:
Note:
• If your system is a 5104-22C or 9006-22C, go to “5104-22C or 9006-22C locations” on page 63 to
identify the physical location and removal and replacement procedure.
Beginning troubleshooting and problem analysis 49
Содержание Power Systems Series
Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...
Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...
Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...
Страница 133: ......
Страница 134: ...IBM...