browser. For example, if you connected your PC or notebook computer to HMC1, type
https://169.254.2.147
in your PC's or notebook computer's web browser.
6.
When the login display appears, enter one of the following default user IDs and passwords.
Table 20. Default user IDs and passwords for the web interface
User ID
Password
general
general
admin
admin
7.
Change the default password when prompted.
8.
If you plan to connect your PC or notebook computer to your network, complete the following steps:
a.
From the navigation area, expand
Network Services
.
b.
Click
Network Configuration
. Do one of the following:
v
If your PC or notebook computer is connected to HMC1, fill in the section labeled Network
interface eth0.
v
If your PC or notebook computer is connected to HMC2, fill in the section labeled Network
interface eth1.
c.
Ensure that the following fields are filled in correctly.
Table 21. Fields and values for network configuration
Field
Value
Configure this interface?
Selected
Type of IP address
Static
IP address
This is the same address that you used in step 5 on page
56.
Subnet mask
255.255.255.0
d.
Click
Save Settings
.
e.
Disconnect your PC or notebook computer from the server.
f.
Connect the server to your company network.
g.
Go to any PC or notebook computer on your company network that is running a supported
browser. For information about supported browsers, see ASMI requirements.
Type the following in the Address field of your browser:
https://host name.domain name
where
host name
and
domain name
are the host name and domain name you entered when
completing step 8c.
h.
Log in to the ASMI.
9.
Set the time of day on the server.
Accessing the Advanced System Management Interface by using an ASCII terminal
You can connect the ASCII console to the server to access the Advanced System Management Interface
(ASMI).
The ASCII interface to the ASMI provides a subset of the web interface functions. The ASCII console is
available only when the system is in platform-standby state. It is not available during the initial program
load (IPL) or run time. The ASMI on an ASCII console is not available during some phases of system
operation, such as the initial program load (IPL) and run time.
To set up the ASCII console for direct or remote access to the ASMI, complete the following tasks:
Common service procedures
57
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...