c.
Press Enter on the Confirm Rebuild Disk Unit Data display. The rebuild process might take
several minutes to complete.
d.
Press F5 to refresh the display until the
Percent complete
shows 5%.
e.
When the display shows at least 5% complete, you can either continue to monitor this display to
completion, or press F3 (Exit) to return to the Work with disk units display.
f.
Press F3 (Exit) to return to the System service tools display.
g.
Press F3 (Exit) to return to the Exit SST display and press Enter.
20.
a.
Select
Replace configured unit
on the Work with Disk unit recovery display. Press Enter.
b.
Select the configured disk drive that you are exchanging (suspended drive) on the Select
Configured Unit to Replace display. Press Enter.
c.
Select the disk drive that you just installed on the Select Replacement Unit display. This drive has
a non-configured status.
Note:
In some cases, it might take several minutes for a new disk drive to display. Repeat these
steps until the new drive is shown.
Press Enter.
d.
Press Enter on the Confirm Replace of Configured Unit display to confirm your choice for
replacement.
The replacement process might take several minutes to complete.
When the process is complete, the Work with Disk unit recovery display is shown.
e.
Press F3 (Exit) to return to the Work with disk units display.
f.
Select
Display disk configuration
on the Work with disk units display.
g.
Select
Display disk configuration status
on the Display Disk Configuration display.
Mirrored status shows Resuming. When complete, the mirrored status shows Active. This process
might take several minutes to complete. You can either monitor this display to completion, or
press F3 (Exit) three times, and then press Enter to return to the main menu.
Was the failing disk drive mirrored?
Yes:
Go to step 22.
No:
Continue with the next step.
21.
To rebuild data on the replacement disk drive, refer to the information for the controller to which
the disk drive is attached:
v
If the disk drive is attached to a PCI-X SCSI RAID controller, see the
PCI−X SCSI RAID Controller
Reference Guide for AIX
.
v
If the disk drive is attached to a PCI SCSI RAID adapter (feature code 2498), see the
PCI
4−Channel Ultra3 SCSI RAID Adapter Reference Guide
.
For more information, see the
AIX System Management Guide: Operating System and Devices
.
22.
Go to Verifying a repair.
This completes this procedure.
Replacing the disk drive using Linux
This procedure is used to replace a disk drive in a location that is controlled by a system or logical
partition that is running the Linux operating system.
Preparing to remove the disk drive
1.
Log in as root user.
2.
Type
iprconfig
on the command line of the Linux session and press Enter.
The IBM Power RAID Configuration Utility display is shown.
3.
Select
Analyze log
. Press Enter. The Kernel Messages Log display is shown.
Common service procedures
89
Содержание Power System POWER7 Series
Страница 1: ...Power Systems Common service procedures...
Страница 2: ......
Страница 3: ...Power Systems Common service procedures...
Страница 8: ...vi...
Страница 125: ...Figure 48 Lift up on the EMC shield Common service procedures 111...
Страница 139: ...Figure 60 Lift up on the EMC shield Common service procedures 125...
Страница 186: ...172...
Страница 196: ...182...
Страница 197: ......
Страница 198: ...Printed in USA...