If
Then
Yes:
Continue with step 6.
No:
Continue with step 9.
6.
To locate the device by using the identify LED, complete the following steps:
a.
The operating system log contains information about the device in the form sdx, where x is the
letter associated with the drive that failed. Record the sdx information for the device that failed.
For example, the failing device in the following operating system log is sdb:
[ 2614.698832]
blk_update_request: I/O error, dev sdb, sector 131072
b.
At the command prompt, type
hdparm -i /dev/sdx
, where
sdx
is the device information recorded
in step 6a. Then, press Enter.
c.
Record the serial number of the device.
d.
At the command prompt, type
arcconf getconfig 1 PD
and press Enter. Find the reported channel
and device numbers for the device that has the same serial number that you recorded in the
previous step. Record the reported channel and device numbers.
e.
At the command prompt, type
arcconf identify 1 device x y start
, where x is the reported
channel number and y is the reported device number that you recorded in the previous step.
Then, press Enter.
Is the identify LED for one of the devices flashing?
If
Then
Yes:
Continue with the next step.
No:
Continue with step 9.
7.
Replace the device with the flashing identify LED. Go to “8348-21C locations” on page 133 to identify
the removal and replacement procedure. After you have replaced the device, continue with the next
step.
8.
At the command prompt, type
arcconf identify 1 device x y stop
, where x is the reported channel
number and y is the reported device number that you recorded in step 6d. Then, press Enter. This
ends the procedure.
9.
To locate the device by using the device serial number, complete the following steps:
a.
The operating system log contains information about the device in the form sdx, where x is the
letter associated with the drive that failed. Record the sdx information for the device that failed.
For example, the failing device in the following operating system log is sdb:
[ 2614.698832]
blk_update_request: I/O error, dev sdb, sector 131072
b.
At the command prompt, type
hdparm -i /dev/sdx
, where
sdx
is the device information recorded
in step 9a. Then, press Enter.
c.
Record the serial number of the device.
d.
Power off the system. Remove one device at a time until you identify the device with the serial
number identified in step 9c. Replace only the device with the matching serial number. Reinstall
the other devices. Go to “8348-21C locations” on page 133 to identify the removal and replacement
procedure. This ends the procedure.
User guides for GPUs and PCIe adapters
Use this information to find the user guide for your graphics processing unit (GPU) or PCIe adapter.
Use the following table to find the user guide for the GPU or PCIe adapter that you are using.
Beginning troubleshooting and problem analysis
25
Содержание Power System 8335-GCA
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 133: ...System parts Figure 6 System parts Finding parts and locations 117 ...
Страница 160: ...144 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 172: ...156 Problem analysis system parts and locations for the 8335 GCA 8335 GTA 8335 GTB and 8348 21C ...
Страница 173: ......
Страница 174: ...IBM ...