IBM Power System 8247-21L Скачать руководство пользователя страница 25

Table 5. PCIe adapter slot priorities and maximum adapters supported in the 5148-21L, 5148-22L, 8247-21L,
8247-22L, 8284-21A, or 8284-22A system (continued)

Feature code

Description

8247-21L or 5148-21L

8247-22L or 5148-22L

8284-21A
1 processor

8284-22A
1 processor

8284-22A
2 processors

Slot priorities

Maximum
number of
adapters
supported

Slot priorities

Maximum
number of
adapters
supported

Slot priorities

Maximum
number of
adapters
supported

Slot priorities

Maximum
number of
adapters
supported

Slot priorities

Maximum
number of
adapters
supported

EC3E

PCIe3 2-port 100 Gb
EDR IB Adapter x16
(FC EC3E and EC3F;
CCIN 2CEA); Adapter
FRU number:
00WT075

v

PCIe3 x16

v

Short, low-profile
(FC EC3E)

v

Short, with
full-height tailstock
(FC EC3F)

v

OS support: Linux
operating system

5, 6

2

5, 2, 6, 4

4

Not
supported

Not
supported

5, 6

2

4, 6, 2, 5

4

EC3L

PCIe3 2-port 100 GbE
(NIC and RoCE)
QSFP28 Adapter (FC
EC3L and EC3M;
CCIN 2CEC); Adapter
FRU number:
00WT078

v

PCIe3 x16

v

Short, low-profile
(FC EC3L)

v

Short, with
full-height tailstock
(FC EC3M)

v

NIC and IBTA
RoCE standards

v

OS support: AIX,
IBM i, and Linux
operating systems

5, 6

2

5, 2, 6, 4

4

Not
supported

Not
supported

5, 6

2

4, 6, 2, 5

4

EC3T

PCIe3 LP 1-port 100
Gb EDR InfiniBand
Adapter x16 (FC
EC3T; CCIN 2CEB)
Adapter FRU number:
00WT013

v

PCIe3 x16

v

Short, low-profile

v

OS support: Linux
operating systems

5, 6

2

5, 2, 6, 4

4

Not
supported

Not
supported

5, 6

2

4, 6, 2, 5

4

EC37

4

PCIe3 LP 2-port 10
GbE NIC and RoCE
SFP+ Copper Adapter
(FC EC37; CCIN
57BC); Adapter FRU
number: 00RX859

v

PCIe3 x8

v

Low-profile adapter

v

Extra-high
bandwidth, low
latency 10 Gb
Ethernet

v

10 Gb SFP+ ports
can function in the
NIC

v

OS support: AIX,
IBM i only with
VIOS, and Linux
operating systems

Not
supported

Not
supported

Not
supported

Not
supported

Not
supported

Not
supported

5, 6, 8

2

, 10, 11

5

5, 2, 6, 4, 1,
8

2

, 10, 11

8

PCIe adapter placement

9

Содержание Power System 8247-21L

Страница 1: ...Power Systems PCIe adapter placement for the 5148 21L 5148 22L 8247 21L 8247 22L 8284 21A or 8284 22A IBM...

Страница 2: ......

Страница 3: ...Power Systems PCIe adapter placement for the 5148 21L 5148 22L 8247 21L 8247 22L 8284 21A or 8284 22A IBM...

Страница 4: ...Notices manual G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER8 processor and to all associated models Cop...

Страница 5: ...Ie adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I O expansion drawer 21 Related procedures for PCI adapter placement 29 Finding the current system configuration in IBM i 29 Notic...

Страница 6: ...iv Power Systems PCIe adapter placement for the 5148 21L 5148 22L 8247 21L 8247 22L 8284 21A or 8284 22A...

Страница 7: ...tional copies of safety information documentation can be obtained by calling the IBM Hotline at 1 800 300 8751 German safety information Das Produkt ist nicht f r den Einsatz an Bildschirmarbeitspl tz...

Страница 8: ...thing unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PDP and remove...

Страница 9: ...mperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure that air flow is...

Страница 10: ...Verify that the route that you choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet v Verify t...

Страница 11: ...DANGER Rack mounted devices are not to be used as shelves or work spaces L002 L003 1 2 or 1 2 or 1 2 3 4 or Safety notices ix...

Страница 12: ...iple AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 L008 x Power Systems PCIe adapt...

Страница 13: ...tacle Although shining light into one end and looking into the other end of a disconnected optical fiber to verify the continuity of optic fibers many not injure the eye this procedure is potentially...

Страница 14: ...t use on uneven surface incline or decline major ramps v Do not stack loads v Do not operate while under the influence of drugs or alcohol v Do not support ladder against LIFT TOOL v Tipping hazard Do...

Страница 15: ...ing interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE and require isolation from the exposed OSP cabling The addition of primary protectors is not sufficient protection to connect th...

Страница 16: ...xiv Power Systems PCIe adapter placement for the 5148 21L 5148 22L 8247 21L 8247 22L 8284 21A or 8284 22A...

Страница 17: ...dapter 5772 10 Gb Ethernet LR PCI Express Adapter EC2G and EL39 PCIe LP 2 Port 10 GbE SFN6122F Adapter EC2J PCIe 2 Port 10 GbE SFN6122F Adapter EC41 PCIe2 LP 3D Graphics Adapter x1 EL3Z PCIe2 LP 2 por...

Страница 18: ...switches follow v PCIe3 Switch 1 that provides PCIe buses from Processor Module 1 Chip 0 v PCIe3 Switch 2 that provides PCIe buses from Processor Module 1 Chip 1 Table 3 lists the features provided b...

Страница 19: ...P1 C21 6 PCIe3 x8 Processor Module 2 Chip 1 PHB1 Low profile No Yes Yes 5 No Yes Slot 2 P1 C31 PCIe3 x16 Processor Module 2 Chip 1 PHB0 Low profile Yes Yes Yes 9 No Yes Slot 3 P1 C41 6 PCIe3 x8 Proces...

Страница 20: ...platforms with less than 64GB of total system memory SR IOV should not be configured in these slots as performance may be severely impacted v All slots are PCIe generation 3 slots v The peak bandwidt...

Страница 21: ...21A or 8284 22A system Feature code Description 8247 21L or 5148 21L 8247 22L or 5148 22L 8284 21A 1 processor 8284 22A 1 processor 8284 22A 2 processors Slot priorities Maximum number of adapters sup...

Страница 22: ...supported Not supported Not supported Not supported Not supported 5 6 82 10 11 5 5 6 82 10 11 5 5 2 6 4 1 82 10 11 8 5274 2 port Gb Ethernet SX PCI Express Adapter FC 5274 CCIN 5768 Adapter FRU numbe...

Страница 23: ...2 10 11 8 5281 1 Gb Ethernet UTP 2 port PCIe Adapter FC 5281 CCIN 5767 Adapter FRU number 46K6601 v PCIe2 x8 v Short low profile OS support Linux operating system 11 10 82 6 5 5 11 1 10 82 2 6 4 5 8 N...

Страница 24: ...8 v Short low profile v High bandwidth v Supports Solarflare OpenOnload v OS support Linux operating system Not supported Not supported Not supported Not supported Not supported Not supported 5 6 82 1...

Страница 25: ...4 6 2 5 4 EC3L PCIe3 2 port 100 GbE NIC and RoCE QSFP28 Adapter FC EC3L and EC3M CCIN 2CEC Adapter FRU number 00WT078 v PCIe3 x16 v Short low profile FC EC3L v Short with full height tailstock FC EC3M...

Страница 26: ...2 6 4 5 8 EC45 PCIe2 LP 4 port USB 3 0 Adapter FC EC45 CCIN 58F9 Adapter FRU number 00E2932 low profile tailstock part number 00E2934 v PCIe 2 2 x1 v Short low profile half length adapter v Provides...

Страница 27: ...dapter FRU number 00MH993 v PCIe3 x4 v Short low profile FC EC56 v Short with full height tailstock FC EC57 v 3 2 TB of low latency flash memory v OS support Linux operating systems 5 6 102 86 11 5 1...

Страница 28: ...r Adapter FC EJ13 CCIN 59AB Adapter FRU number 000NK006 v PCIe3 x8 v Short low profile v Field Programmable Gate Array FPGA accelerator adapter v One PCIe x8 or x16 slot per adapter Low profile v OS s...

Страница 29: ...ed Not supported Not supported Not supported Not supported Not supported EJ1N PCIe1 SAS Tape DVD Dual port 3 Gb x8 Adapter FC EJ1P and EJ1N CCIN 57B3 Adapter FRU 44V4852 v PCIe1 x8 v Short low profile...

Страница 30: ...6 2 5 2 6 4 4 Not supported Not supported Not supported Not supported Not supported Not supported EL27 PCIe2 2 port 10 GbE RoCE SFP adapter FC EL27 CCIN EC27 Adapter FRU number 74Y1988 v PCIe2 x8 v S...

Страница 31: ...P Adapter FC EL38 CCIN 2B93 Adapter FRU number 000E9284 v PCIe3 x8 v FCoE or NIC network convergence adapter v 10 Gb SFP ports can function in the NIC or FCoE mode v Supports the SR IOV function v Ext...

Страница 32: ...5 5 2 6 4 1 9 11 8 Not supported Not supported Not supported Not supported Not supported Not supported EL3D PCIe3 LP 2 port 56 Gb FDR IB Adapter x16 FC EL3D CCIN 2CE7 Adapter FRU number 00RX852 v PCIe...

Страница 33: ...GbE NIC and RoCE SR Adapter FC EL40 CCIN 57BE Adapter FRU number 00RX875 v PCIe3 x8 v Short low profile v Extra high bandwidth low latency 10 Gb Ethernet v 10 Gb SFP ports can function in the NIC v V...

Страница 34: ...annel Adapter FC EL5Y and EL5Z CCIN 578D Adapter FRU number 00WT111 v PCIe2 x8 v Short low profile FC EL5Y v Short plus SFF Host Bus Adapter HBA with full height tailstock FC EL5Z v Extra high bandwid...

Страница 35: ...2 6 4 1 9 11 8 EN0L PCIe3 LP 4 port 10 Gb FCoE and 1 GbE Copper and RJ45 Adapter FC EN0L CCIN 2CC1 Adapter FRU number 00E3502 v PCIe3 x8 v Short low profile v Fibre Channel over Ethernet FCoE converg...

Страница 36: ...6 82 10 11 5 5 2 6 4 1 82 10 11 8 5 6 82 10 11 5 5 6 82 10 11 5 5 2 6 4 1 82 10 11 8 EN0V PCIe2 LP 4 port 10 Gb 1 GbE Copper SFP RJ45 Adapter FC EN0V CCIN 2CC3 Adapter FRU number 00E2715 low profile t...

Страница 37: ...upported in slots 7 8 9 10 and 11 4The adapters FCs EC37 and EC2M are not supported in the 8284 22A system with processor card FCs EPXL and ELPF 5The adapters FC EJ16 EJ17 and EJ18 are not compatible...

Страница 38: ...t 4 P1 C4 PCIe3 x16 Yes1 Yes2 No Slot 5 P1 C5 PCIe3 x8 No Yes2 No Slot 6 P1 C6 PCIe3 x8 No No No Slot 7 P2 C1 PCIe3 x16 Yes Yes Yes3 Slot 8 P2 C2 PCIe3 x8 No Yes2 No Slot 9 P2 C3 PCIe3 x8 No No No Slo...

Страница 39: ...uses v All slots support enhanced error handling EEH v All PCIe slots are hot swappable and support concurrent maintenance PCIe adapters placement rules Use this information while selecting slots for...

Страница 40: ...PCIe2 FH 4 port 8 Gb74Y3467 Fibre Channel Adapter FC 5729 CCIN 5729 Adapter FRU number 74Y3467 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 5735 8 Gb PCI Express Dual port Fibre Channel Adapter FC 5735 CCIN 577D...

Страница 41: ...FRU number 44V4852 2 8 5 11 3 9 6 12 1 7 4 10 6 6 6 5913 PCIe2 1 8 GB Cache RAID SAS Tri port 6 Gb Adapter FC 5913 CCIN 57B5 Adapter FRU number 00J0596 1 7 4 10 2 8 3 9 5 11 6 12 6 6 6 EC28 PCIe2 2 p...

Страница 42: ...0 3 9 6 12 4 4 4 EJ14 PCIe3 12 GB Cache RAID PLUS SAS Adapter Quad port 6 Gb x8 FC EJ14 CCIN 57B1 Adapter FRU number 01DH742 1 7 4 10 3 9 6 12 4 4 4 EJ1P PCIe1 SAS Tape DVD Dual port 3 Gb x8 Adapter F...

Страница 43: ...4 10 2 8 3 9 5 11 6 12 6 6 0 EL57 PCIe2 4 port 10 Gb FCoE and 1 GbE Copper and RJ45 Adapter FC EL57 CCIN 2CC1 Adapter FRU number 00E8140 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 EL58 8 Gb PCI Express Dual po...

Страница 44: ...r FC EN0U CCIN 2CC3 Adapter FRU number 00E2715 low profile tailstock 00E2720 1 7 4 10 2 8 3 9 5 11 6 12 6 6 0 EN0W PCIe2 2 port 10 GbE BaseT RJ45 Adapter FC EN0W CCIN 2CC4 Adapter FRU number 00E2714 1...

Страница 45: ...m configuration start an IBM i session and sign on If you have more than one system start a session on the system that is being upgraded and for which you have service tools authority To find the curr...

Страница 46: ...21L 8247 22L 8284 21A or 8284 22A on page 1 v Yes Do the following tasks a Type 9 for the System Expansion Unit field and press Enter b Repeat steps 7 11 for each expansion unit c Select an available...

Страница 47: ...efore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be in...

Страница 48: ...itical operations Users should periodically check IBM s support websites for updated information and fixes applicable to the system and related software Homologation statement This product may not be...

Страница 49: ...www ibm com able Privacy policy considerations IBM Software products including software as a service solutions Software Offerings may use cookies or other technologies to collect product usage inform...

Страница 50: ...nstalled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfer...

Страница 51: ...dard of the VCCI Council If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions Japan Electronics and Inform...

Страница 52: ...tion This is a Class A product In a domestic environment this product may cause radio interference in which case the user may need to perform practical action Electromagnetic Interference EMI Statemen...

Страница 53: ...ustimmung von IBM ver ndert bzw wenn Erweiterungskomponenten von Fremdherstellern ohne Empfehlung von IBM gesteckt eingebaut werden EN 55022 EN 55032 Klasse A Ger te m ssen mit folgendem Warnhinweis v...

Страница 54: ...he instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful...

Страница 55: ...esponsibility for any failure to satisfy the protection requirements resulting from a non recommended modification of the product including the fitting of non IBM option cards European Community conta...

Страница 56: ...die Grenzwerte der EN 55022 EN 55032 Klasse B ein Um dieses sicherzustellen sind die Ger te wie in den Handb chern beschrieben zu installieren und zu betreiben Des Weiteren d rfen auch nur von der IB...

Страница 57: ...that all proprietary notices are preserved You may not distribute display or make derivative works of these publications or any portion thereof without the express consent of IBM Commercial Use You m...

Страница 58: ...42 Power Systems PCIe adapter placement for the 5148 21L 5148 22L 8247 21L 8247 22L 8284 21A or 8284 22A...

Страница 59: ......

Страница 60: ...IBM...

Отзывы: