Did the operating system load successfully?
Yes:
Go to step 5.
No:
Continue with the next step.
4.
Choose from the following options:
v
If the original problem was a failing disk drive that contained the operating system software, go to step 5.
v
If the original problem was that the operating system would not load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
v
If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v
If the original problem was that the operating system would not load and you have an isolation procedure to
complete, perform the isolation procedure.
v
If the original problem was that the operating system would not load and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v
If you have a new problem, perform problem analysis and repair the new problem.
5.
Choose from the following options:
v
v
“Verifying the repair in Linux” on page 71
v
“Verifying a repair by using an IBM i system or logical partition” on page 69
Verifying the repair in AIX
You can use this procedure to verify that a repair is complete using the AIX operating system.
Use this maintenance analysis procedure (MAP) to check out the server after a repair is completed.
1.
Did you replace a disk drive in the root volume group?
No
Go to step 3.
Yes
Continue with the next step.
2.
Run stand-alone diagnostics either from a CD or from a Network Installation Management (NIM)
server.
Did you encounter any problems?
No
Reinstall the operating system and continue with step 5 on
page 67.
Yes
If the original problem still exists, replace the
field-replaceable unit (FRU) or perform the isolation
procedure that is next in the FRU list. If you have reached
the end of the FRU list, contact your next level of support.
If a new problem has occurred, go to Beginning problem
analysis.
3.
Did you replace a FRU with the power turned on and concurrently with system operations?
No
Go to step 5 on page 67.
Yes
Continue with the next step.
4.
Did you use an AIX diagnostics service aid hot-swap operation to change the FRU?
66
Power Systems: System backplane for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
Содержание Power 730 Express 8231-E2B
Страница 1: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 2: ......
Страница 3: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 14: ...2 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 44: ...32 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 110: ...98 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 111: ......
Страница 112: ...IBM Printed in USA...