3.
In the navigation area, click System Actions > Attention LED.
4.
Click Turn Attention LED Off. A confirmation window that provides the following information is
displayed.
– A verification that the system attention LED was deactivated.
– An indication that there still might be open problems within the system.
5.
Click OK.
Deactivating an identify LED for a FRU by using the HMC
Learn how to deactivate an identify LED by using the Hardware Management Console (HMC).
To deactivate an identify LED for a FRU by using the HMC, complete the following steps:
1.
Choose one of the following navigation options depending on the interface type of the HMC:
v
If you are using an HMC Classic or HMC Enhanced interface, complete the following steps:
a.
In the navigation area, click Systems Management > Servers.
b.
In the content pane, select the system.
c.
Click Tasks > Operations > LED Status > Identify LED. The Identify LED, Select Enclosure
window is displayed.
v
If you are using an HMC En Tech Preview (Pre-GA) or HMC E interface,
complete the following steps.
a.
In the navigation area, click the Resources icon
, and then click All Systems.
b.
To view the actions for that server, click the name of the required server.
c.
In the navigation area, click System Actions > Attention LED > Identify Attention LED. The
Identify LED, Select Enclosure window is displayed.
2.
To deactivate an identify LED for a FRU, select an enclosure from the table, and then click Selected >
List FRUs
.
3.
Select one or more FRUs from the table, and click Deactivate LED. The associated LED is turned off.
Deactivating an identify LED for an enclosure by using the HMC
Learn how to deactivate an identify LED by using the Hardware Management Console (HMC).
To deactivate an identify LED for an enclosure by using the HMC, complete the following steps:
1.
Choose one of the following navigation options depending on the interface type of the HMC:
v
If you are using an HMC Classic or HMC Enhanced interface, complete the following steps:
a.
In the navigation area, click Systems Management > Servers.
b.
In the content pane, select the system.
c.
Click Tasks > Operations > LED Status > Identify LED.
v
If you are using an HMC En Tech Preview (Pre-GA) or HMC E interface,
complete the following steps.
a.
In the navigation area, click the Resources icon
, and then click All Systems.
b.
To view the actions for that server, click the name of the required server.
c.
In the navigation area, click System Actions > Attention LED > Identify Attention LED.
2.
To deactivate an identify LED for an enclosure, select an enclosure from the table, and click
Deactivate LED
. The associated LED is turned off.
Common procedures for removing or replacing the PCIe3 x8 SAS RAID internal adapter 6 Gb
99
Содержание PCIe3 x8 SAS RAID internal adapter 6 Gb
Страница 2: ......
Страница 8: ...vi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Страница 18: ...xvi PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Страница 36: ...18 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Страница 118: ...100 PCIe3 x8 SAS RAID internal adapter 6 Gb ...
Страница 129: ...Notices 111 ...
Страница 130: ...IBM Printed in USA ...