Table 19. PCI expansion card problem isolation procedure
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
v
If an action step is preceded by “Trained service technician only,” that step must be performed only by a
trained service technician.
Symptom
Action
A B700xxxx error message indicates a problem with a PCI
expansion card.
1.
Collect the error log information.
2.
Get the DSA, which is word 7 of the associated
B700xxxx SRC.
3.
Use the hexadecimal value of the DSA to
determine the location code of the failing CRU.
For the IBM Flex System p260 Compute Node:
v
If the value is 02000000 or 02100000, the location
code is P1-C18.
v
If the value is 02020000 or 02110000, the location
code is P1-C19.
For the IBM Flex System p460 Compute Node:
v
If the value is 02010000, 02020000, or 02100000,
the location code is P1-C34.
v
If the value is 02030000, 02110000, or 02120000,
the location code is P1-C35.
v
If the value is 02210000, 02220000, or 02300000,
the location code is P1-C36.
v
If the value is 02230000, 02310000, or 02320000,
the location code is P1-C37.
4.
Replace the device that you just installed.
Hypervisor problems
The hypervisor provides error diagnostics with associated error codes, isolation procedures, and symbolic
failing items for troubleshooting.
Table 20 describes the isolation procedures and the symbolic failing items.
Table 20. Hypervisor isolation procedures and symbolic failing items
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine
which components are CRUs and which components are FRUs.
v
If an action step is preceded by Trained service technician only, that step must be performed only by a trained
service technician.
Isolation
procedure or
symbolic failing
item
Symptom
Action
ANYPROC
The failing
component is one of
the system
processors.
Replace the system-board and chassis assembly, as described in
“Replacing the system-board and chassis assembly” on page 83.
Chapter 8. Troubleshooting
463
Содержание P260
Страница 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 2: ......
Страница 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Страница 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Страница 523: ...Appendix Notices 511 ...
Страница 524: ...IBM Printed in USA ...