6. Unplug the power-distribution strip power cord going to the UPS.
7. Remove the UPS bracket
F
.
a. Loosen the two screws
G
(for a BK500 series UPS) or
H
(for a BK650
UPS) and secure the UPS bracket to the metal support on the front inside
of the enclosure.
b. Lift the UPS bracket
F
up and out of the metal support
I
.
E
F
G
H
I
J
J
K
8. Attach the following cables to the UPS.
a. Connect the RS-232 interface cable to the rear panel of the UPS.
Note:
This connection enables the NetVista Kiosk to monitor the life of the
backup battery.
b. Plug the power distribution strip power cord into the black outlet located at
the rear of the UPS.
9. Route the UPS power cable out the back of the enclosure or through the center
of the floor-mount plate to an ac power outlet location.
10. Insert the UPS
E
into the front of the enclosure with the cable end on the
bottom and the UPS feet against the inside wall. Guide the UPS down onto the
metal support
I
located close to the bottom front of the enclosure.
11. Reinstall the UPS bracket
F
and tighten the two screws
G
or
H
on the
bracket.
The NetVista Kiosk-DBCS Model
27
Содержание NetVista Kiosk DBCS
Страница 1: ...NetVista Kiosk 4835 120 DBCS Model Printer Feature Hardware Service Manual Supplement GY18 2417 00 ...
Страница 2: ......
Страница 3: ...NetVista Kiosk 4835 120 DBCS Model Printer Feature Hardware Service Manual Supplement GY18 2417 00 ...
Страница 6: ...iv ...
Страница 37: ...The NetVista Kiosk DBCS Model 31 ...
Страница 38: ... Part Number 57P4240 Printed in Japan GY18 2417 00 1P P N 57P4240 ...