30
IBM Netfinity FAStT500 RAID Controller Enclosure Unit Installation Guide
Controller unit and drive enclosure cabling overview
The controller unit supports redundant drive loops. A redundant drive loop consists of one
or more drive enclosures connected to a controller using two sets of data cables. If one
data path fails, the controller uses the other data path to maintain I/O to the drive group.
shows a storage subsystem containing one controller enclosure unit and two
drive groups with four drive enclosures each. Each drive group uses redundant drive loops
to connect to the controller unit. Loop A and Loop B make up one redundant pair of drive
loops. Loop C and Loop D make up a second redundant pair.
Attention: To prevent loss of drive enclosure redundancy, cable the drive enclosures as
shown in the following figure.
Figure 18. Redundant drive loop cabling overview
Drive Loop D
Drive Loop A
Drive Loop B
Drive Loop C
Drive enclosure
Group 1
Drive enclosure
Group 2
Controller unit
Содержание Netfinity FAStT500
Страница 1: ......
Страница 2: ......
Страница 3: ...Netfinity FAStT500 RAID Controller Enclosure Unit Installation Guide ...
Страница 7: ...v Index 63 ...
Страница 8: ...vi IBM Netfinity FAStT500 RAID Controller Enclosure Unit Installation Guide ...
Страница 38: ...22 IBM Netfinity FAStT500 RAID Controller Enclosure Unit Installation Guide ...
Страница 56: ...40 IBM Netfinity FAStT500 RAID Controller Enclosure Unit Installation Guide ...
Страница 83: ... Part Number 19K0788 Printed in U S A April 2000 19K0788 ...