IBM Netfinity FAStT500 RAID Controller Enclosure Unit User’s Reference
Overtemperature condition and power supply shutdown
If the fan and communications module fails or is unable to maintain an internal
temperature below 70
o
C (158
o
F), one or both of the power supplies in the controller unit
might shut down (see
). If both power supplies shut down, the controller unit is
not operational.
Figure 12. Fan and communications and power supply fault indicators
The storage-management software causes the fault indicator to light before the
temperature has risen sufficiently to shut down the power supplies. The light comes on
when the controller unit temperature exceeds 45° C (113° F). The controller unit shuts
down if the temperature rises to 70° C (158° F). See
for the location of the
controller fan fault indicator. If both power supplies shut down, the fault indicator cannot
come on.
Figure 13. Overtemperature indicator
Fan and
communications fault
indicator
Fan and
communications
module
Power supplies
Power supply fault
indicators
Controller fan
fault indicator
Содержание Netfinity FASt T500
Страница 1: ......
Страница 2: ......
Страница 3: ...Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 12: ...x IBM Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 16: ...xiv IBM Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 20: ...xviii IBM Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 28: ...8 IBM Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 48: ...28 IBM Netfinity FAStT500 RAID Controller Enclosure Unit User s Reference...
Страница 91: ...Part Number 19K8461 Printed in U S A April 2000 19K8461...