Mappings

49

4.2 Source Accesses

The Modbus Plus driver supports four possible source accesses.

The first source defines a local address which allows any device on the
Modbus Plus network to write the data to the X-Link. This type of source is
ideal for data that changes infrequently, but must be forwarded immediately,
such as errors or exceptions. Programming must be provided on the remote
device to update the data when necessary.

The second type of source supported by the Modbus Plus driver is an X-Link
initiated read. This source defines an external address which the X-Link uses
to read the data from a remote node on the network. This access also requires
you to specify when to read the data. This type of data source does not
require any programming in the remote node, but generates extra network
bandwidth to poll the data.

The next source is Modbus Plus global data. As each station passes data on
the network, it has the opportunity to transmit up to 32 integers to all the
other stations on the network. This global data can be accessed as a source
for an X-Link mapping. To access global data, you provide a station address
(1 to 64) and an offset into that station's global data table.

The last source is Modbus Plus network statistic counters. To access the
counters stored on the SA85 card, provide an offset specifying the number of
words to skip from the beginning of the diagnostic counters.

Содержание Modbus Plus

Страница 1: ...Modbus Plus X Link Driver User s Guide Version 1 22 50 Northland Road Waterloo Ontario CANADA N2V 1N3 Tel 519 725 5136 Fax 519 725 1515 www sstech on ca...

Страница 2: ...of Woodhead Canada Limited SST is a trademark of Woodhead Industries Inc X Link is a registered trademark of Woodhead Canada Limited All other trade names are trademarks or registered trademarks of t...

Страница 3: ...an I Find More Help 42 2 Communication 43 2 1 Requirements 44 2 2 Compatibilities 44 3 Configuration 45 3 1 Configuration Parameters 46 4 Mappings 47 4 1 Data Types and Lengths 48 4 2 Source Accesses...

Страница 4: ...Modbus Plus X Link Driver User s Guide 38...

Страница 5: ...Introduction 39 1 Introduction 1 1 What is the Modbus Plus Driver The Modicon Modbus Plus X Link driver allows the X Link to transfer data to or from devices on the Modicon Modbus Plus network...

Страница 6: ...s troubleshooting information and technical specifications that can be referenced when required For further information refer to the SA85 Interface Card User s Guide Modicon IBM Host Based Devices Use...

Страница 7: ...From the Ports list select the COM port you are using Text in Message Boxes appears in quotation marks For example The message Already Downloaded Reload appears Keystrokes Single keystrokes appear in...

Страница 8: ...n contact X Link Technical Support by mail fax or email or by phone during regular business hours EST X Link Technical Support SST a division of Woodhead Canada Limited 50 Northland Road Waterloo Onta...

Страница 9: ...Once configured the X Link emulates a station on the Modbus Plus network It can send messages to other stations and receive messages from other stations This section outlines the requirements and comp...

Страница 10: ...upports either the redundant or non redundant version of the SA85 Installation and cabling requirements are detailed in the SA85 user manual Modicon IBM Host Based Devices User s Guide GM HBDS 001 Rev...

Страница 11: ...ion When you download a driver to the X Link you must set configuration parameters to control the interface between the driver and the required hardware This section details the configuration paramete...

Страница 12: ...coming integers will be expanded to floats the floats written to the Modbus Plus will be truncated When this option is off the floating points will be read and written as two consecutive integers Defa...

Страница 13: ...oaded you can create mappings to transfer data from one network to the other This section outlines the mapping options supported by the Modbus Plus driver For information on what mappings are or how t...

Страница 14: ...loating point after retrieval when floating points are requested The type of Modbus Plus command that the driver generates depends on the address type specified The length of the data portion in a com...

Страница 15: ...from a remote node on the network This access also requires you to specify when to read the data This type of data source does not require any programming in the remote node but generates extra netwo...

Страница 16: ...The second type of destination access supported by the Modbus Plus driver is an X Link initiated write This destination defines an external address which the X Link uses to write the data to a remote...

Страница 17: ...xxx INPUT STATUS 1xxxxx INPUT REGISTERS 3xxxxx HOLDING REGISTERS 4xxxxx where xxxxx represents a decimal number from 1 to 65535 4 5 External Addresses Mappings which require the X Link to originate co...

Страница 18: ...events and errors The Status menu allows you to monitor some of these counters As well the status counters can be accessed as a data source for mappings The Modbus Plus driver status counters include...

Страница 19: ...r the status of your Modbus Plus driver you most likely have the memory address set incorrectly Refer to your SA85 User Manual to confirm your settings The configuration software can be used to monito...

Страница 20: ...Modbus Plus X Link Driver User s Guide 54...

Страница 21: ...ver CMOS Storage Requirements Driver Code and Parameters 16 Kbytes Each Global Data Read Address 4 bytes Each Global Data Write Address 3 bytes Each Internal Address 5 bytes Each External Address 10 b...

Страница 22: ...Modbus Plus X Link Driver User s Guide 56...

Отзывы: