Install the Device Using a Lift
1.
Ensure the rack is in its permanent location and is secured to the building. Ensure
that the installation site allows adequate clearance for both airflow and
maintenance. For details, see the
IBM Ethernet Appliance J58S Hardware Guide
.
2.
Load the device onto the lift, making sure it rests securely on the lift platform
(see Figure 4 on page 9).
Figure 4: Load the Device onto the Lift
g004081
3.
Using the lift, position the device in front of the rack or cabinet, centering it in
front of the mounting shelf.
4.
Lift the chassis approximately 0.75 in. above the surface of the mounting shelf
and position it as close as possible to the shelf.
5.
Carefully slide the device onto the mounting shelf so that the bottom of the
chassis and the mounting shelf overlap by approximately two inches.