b.
DCA
2-RH
at
location
M32
35.
Power
on
the
system.
See
36.
Did
the
system
stop
with
the
same
error
code
as
recorded
in
step
1
(See
page
?
v
Yes:
Continue
with
the
next
step.
v
No:
The
book
just
replaced
was
defective.
Return
the
system
to
its
original
configuration.
See
This
ends
the
procedure.
37.
Power
off
the
system.
See
Then,
make
sure
all
amber
logic-power
LEDs
of
all
installed
processor
subsystem
DCAs
are
off.
38.
Remove
the
new
book
that
was
just
installed
in
step
34
(See
page
and
reinstall
the
original
book.
39.
Have
all
the
books
listed
in
step
34
(See
page
been
replaced
with
new
or
original
books?
v
Yes:
Continue
with
the
next
step.
v
No:
Go
to
step
34
(See
page
.
40.
Examine
the
amber
logic-power
LEDs
of
all
installed
processor
subsystem
DCAs.
41.
Are
all
amber
logic-power
LEDs
of
all
installed
processor
subsystem
DCAs
off?
v
Yes:
Continue
with
the
next
step.
v
No:
Replace
the
DCA
that
has
the
amber
logic
power
LED
that
did
not
turn
off.
See
symbolic
FRU
42.
Attention:
Before
replacing
the
system
backplane,
call
your
next
level
of
support.
Then,
replace
the
system
backplane
at
location
MB1.
See
for
part
number
and
remove
and
replace
information.
43.
Power
on
the
system.
See
44.
Did
the
system
stop
with
the
same
error
code
as
recorded
in
step
1
(See
page
?
v
Yes:
Continue
with
the
next
step.
v
No:
The
system
backplane
was
defective.
Return
the
system
to
its
original
configuration.
See
This
ends
the
procedure.
45.
Power
off
the
system.
See
Then,
make
sure
all
amber
logic-power
LEDs
of
all
installed
processor
subsystem
DCAs
are
off.
46.
Has
the
system
backplane
been
replaced?
v
Yes:
Call
your
next
level
of
support.
v
No:
Go
to
step
42
(See
page
.
MAPPWR-F:
Cable
problem
in
power
subsystem
For
use
by
authorized
service
providers.
Note:
Read
the
Danger
and
caution
notices
in
the
introduction
before
performing
this
procedure.
Important:
Always
ensure
that
the
opposite
side
cable
for
the
unit
that
you
are
replacing
is
connected
correctly
before
attempting
concurrent
maintenance.
1.
Find
the
error
code
and
in
the
table
below
that
sent
you
to
this
procedure.
Record
the
associated
FRUs
listed
in
the
Action
column.
Table
1.
Error
codes
Error
code
Action
1xxA
x115
BPC-A
MDA-1
BPC-A-J04
to
MDA-1-J01
cable
Analyze
hardware
problems
395