8.
Perform
steps
23
(See
page
to
24
(See
page
,
and
return
here
after
completion.
Did
the
completion
of
these
steps
resolve
SRC
1xxx
1203
or
1403?
v
No
:
Replace
the
This
ends
the
procedure.
v
Yes
:
This
ends
the
procedure.
9.
Is
the
SRC
1xxx
1204
or
1404?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
13
(See
page
.
10.
Perform
the
following:
a.
Remove
load
cards
Mxx
in
table
below
for
application.
The
possible
failing
loads
are:
Model
Load
position
840/SB3
M20,
M21,
M23,
M24-
memory
b.
Power
on
the
system.
Does
the
system
power
on?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
23
(See
page
.
11.
Perform
the
following:
a.
Power
off
the
system.
b.
Reinstall
one
of
the
Mxx
load
cards
that
was
removed
in
step
10
(See
page
.
c.
Power
on
the
system.
Does
the
system
power
on?
v
Yes
:
Continue
with
the
next
step.
v
No
:
The
last
card
that
was
reinstalled
in
this
step
is
the
failing
item.
This
ends
the
procedure.
12.
Have
all
the
Mxx
load
cards
been
reinstalled?
v
Yes
:
This
ends
the
procedure.
v
No
:
Repeat
step
11
(See
page
.
13.
Is
the
SRC
1xxx
1205
or
1405?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
17
(See
page
.
14.
Perform
the
following:
a.
Remove
load
cards
Mxx
in
table
below
for
application.
The
possible
failing
loads
are:
Model
Load
position
840/SB3
M05,
M18
-
Processors
P0,
P1
b.
Power
on
the
system.
Does
the
system
power
on?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
23
(See
page
.
15.
Perform
the
following:
a.
Power
off
the
system.
b.
Reinstall
one
of
the
Mxx
load
cards
that
was
removed
in
step
14
(See
page
.
c.
Power
on
the
system.
Analyze
hardware
problems
333