You
were
sent
to
this
procedure
with
a
unit
reference
code
of
9052.
If
the
failing
item
is
in
a
migrated
tower,
use
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
to
fix
the
problem.
Otherwise,
contact
your
next
level
of
support
for
assistance.
SDIOP-PIP29:
For
use
by
authorized
service
providers.
You
were
sent
to
this
procedure
from
URC
9012.
The
failing
item
is
in
a
migrated
tower.
Perform
SDIOP-PIP29
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
SDIOP-PIP30:
For
use
by
authorized
service
providers.
Use
this
procedure
to
correct
the
problem
when
the
system
cannot
find
the
required
cache
data
for
the
attached
disk
units.
You
were
sent
to
this
procedure
from
URC
9050.
1.
If
the
system
has
logical
partitions,
perform
this
procedure
from
the
logical
partition
that
reported
the
problem.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Remove
the
I/O
adapter.
Install
the
new
replacement
storage
I/O
adapter
with
the
following
parts
installed
on
it:
Note:
Label
all
parts
(both
old
and
new)
before
moving
them.
v
The
cache
directory
card
from
the
original
storage
I/O
adapter.
See
v
The
removable
cache
card
from
the
original
storage
I/O
adapter
(this
applies
to
only
some
2780
I/O
adapters).
See
v
If
the
I/O
adapter
is
attached
to
an
auxiliary
cache
I/O
adapter,
ensure
that
the
SCSI
cable
on
the
last
port
of
the
new
replacement
storage
I/O
adapter
is
connected
to
the
auxiliary
cache
I/O
adapter.
For
a
list
of
auxiliary
cache
I/O
adapters,
see
3.
Has
a
new
9010
or
9050
SRC
occurred
in
the
Service
Action
Log?
v
No
:
Go
to
step
6
(See
page
v
Yes
:
Continue
with
the
next
step.
4.
Was
the
new
SRC
9050?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Contact
your
next
level
of
support.
This
ends
the
procedure.
5.
The
new
SRC
was
9010.
Reclaim
the
cache
storage.
See
href=
″
rzar5reciopc.htm
″
>Reclaim
IOP
cache
storage.
Note:
When
an
auxiliary
cache
I/O
adapter
that
is
connected
to
the
storage
I/O
adapter
logs
a
9055
SRC
in
the
Product
Activity
Log,
the
reclaim
does
not
result
in
lost
sectors.
Otherwise,
the
reclaim
does
result
in
lost
sectors,
and
the
system
operator
might
want
to
restore
data
from
the
most
recent
saved
tape
after
you
complete
the
repair.
6.
Remove
the
I/O
adapter.
Install
the
new
replacement
storage
I/O
adapter
that
has
the
following
parts
installed
on
it:
v
The
cache
directory
card
from
the
new
storage
I/O
adapter.
See
v
The
removable
cache
card
from
the
new
storage
I/O
adapter
(this
applies
to
only
some
2780
I/O
adapters).
See
208
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation