3.
When
this
procedure
instructs
you
to
power
on
the
system
or
partition,
power
off
or
power
on
only
the
partition
that
reported
the
problem
by
selecting
Work
with
system
partitions
under
SST/DST.
Then,
from
the
Primary
partition,
use
HSM
concurrent
maintenance
to
power
off
the
card
positions
that
you
are
instructed
to
work
with.
The
remove
and
replace
procedures
for
those
positions
will
guide
you
through
the
HSM
concurrent
maintenance
functions.
Use
this
procedure
to
find
the
correct
remove
and
replace
procedure
for
each
card
position
that
you
are
instructed
to
work
with.
4.
Power
off
the
system
or
partition.
5.
Remove
all
of
the
IOAs
that
you
marked
with
an
″
X
″
in
Installed
features
in
a
PCI
bridge
set
form.
Be
sure
to
record
the
card
position
of
each
IOA
so
that
you
can
reinstall
it
in
the
same
position
later.
To
determine
the
remove
and
replace
procedures
for
the
IOAs,
locate
the
IOA
card
positions
in
the
FRU
locations
and
failing
items
table
for
the
frame
type
that
you
recorded.
FRU
locations
and
failing
items
tables
are
in
6.
Power
on
the
system
or
partition.
Does
the
SRC
or
failure
that
sent
you
to
this
procedure
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Power
off
the
system
or
partition.
Go
to
step
12
(See
page
7.
Perform
the
following:
a.
Power
off
the
system
or
partition.
b.
Exchange
the
IOP
that
is
indicated
in
the
DSA.
Be
sure
to
record
the
card
position
of
the
IOPs
so
that
you
can
reinstall
it
in
the
same
position
later.
To
determine
the
remove
and
replace
procedure
for
the
IOP,
locate
the
IOP’s
card
position
in
the
FRU
locations
and
failing
items
table
for
the
frame
type
you
recorded.
FRU
locations
and
failing
items
tables
are
in
c.
Power
on
the
system
or
partition.
Does
the
SRC
or
failure
that
sent
you
to
this
procedure
occur?
v
No
:
Power
off
the
system
or
partition
and
continue
with
the
next
step.
v
Yes
:
Go
to
step
18
(See
page
8.
Install
all
of
the
IOAs
that
you
removed
in
step
5
(See
page
Be
sure
to
install
them
in
their
original
positions.
9.
Power
on
the
system
or
partition.
Does
the
SRC
or
failure
that
sent
you
to
this
procedure
occur?
v
Yes
:
Power
off
the
system
or
partition.
Then,
continue
with
the
next
step.
v
No
:
Perform
This
ends
the
procedure.
10.
Remove
all
of
the
IOAs
that
you
marked
with
an
″
X
″
in
Installed
features
in
a
PCI
bridge
set
form.
Be
sure
to
record
the
card
position
of
each
IOA
so
that
you
can
reinstall
it
in
the
same
position
later.
11.
Remove
the
IOP
that
you
exchanged
and
install
the
original
IOP
in
its
original
position.
12.
Reinstall,
in
its
original
position,
one
of
the
IOA
adapters
that
you
removed.
13.
Power
on
the
system
or
partition.
Does
the
SRC
or
failure
that
sent
you
to
this
procedure
occur?
v
Yes
:
The
I/O
adapter
card
that
you
just
installed
is
the
failing
FRU.
Continue
with
the
next
step.
v
No
:
Power
off
the
system
or
partition.
Repeat
step
12
(See
page
for
another
one
of
the
I/O
adapter
cards
that
you
removed.
If
you
have
reconnected
all
of
the
I/O
adapters
and
the
SRC
or
failure
that
sent
you
to
this
procedure
does
not
occur,
the
problem
is
intermittent.
This
ends
the
procedure.
14.
Power
off
the
system
or
partition.
15.
Exchange
the
I/O
adapter
card
that
you
last
installed.
Be
sure
to
install
the
new
I/O
adapter
card
in
the
same
position.
16.
Power
on
the
system
or
partition.
Analyze
hardware
problems
93