Table
4.
POST
error
messages
(continued)
POST
message
Description
301
and
303
An
error
occurred
during
the
keyboard
and
keyboard
controller
test.
These
error
messages
also
might
be
accompanied
by
continuous
beeping.
Action:
Take
the
following
steps
to
correct
the
problem:
1.
Ensure
that:
v
Nothing
is
resting
on
the
keyboard
and
pressing
a
key.
v
No
key
is
stuck.
v
The
keyboard
cable
is
connected
correctly
to
the
keyboard
and
to
the
correct
connector
on
the
computer.
2.
After
installing
a
USB
keyboard,
you
might
need
to
use
the
Configuration/Setup
Utility
program
to
enable
keyboardless
operation
and
prevent
the
POST
error
message
from
being
displayed
during
startup.
Running
the
diagnostic
tests
can
isolate
the
computer
component
that
failed,
but
you
must
have
your
computer
serviced.
If
the
error
message
remains,
call
for
service.
Note:
If
you
just
connected
a
new
mouse
or
other
pointing
device,
turn
off
the
computer
and
disconnect
that
device.
Wait
at
least
5
seconds;
then,
turn
on
the
computer.
If
the
error
message
goes
away,
replace
the
device.
602
Invalid
diskette
boot
record
Action:
Take
the
following
steps
to
correct
the
problem:
1.
Replace
the
diskette.
2.
If
the
problem
remains,
make
sure
that
the
diskette
drive
cables
are
correctly
and
securely
connected.
3.
If
the
problem
remains,
replace
the
diskette
drive.
If
the
problem
remains,
call
for
service.
604
An
error
occurred
during
a
diskette
drive
test.
Action:
Take
the
following
steps
to
correct
the
problem:
1.
Verify
that
the
Configuration/Setup
Utility
program
correctly
reflects
the
type
of
diskette
drive
that
you
have
installed.
2.
Run
the
diagnostic
tests.
If
the
diagnostic
tests
fail,
call
for
service.
662
A
diskette
drive
configuration
error
occurred.
Action:
If
you
removed
a
diskette
drive,
make
sure
that
the
diskette
drive
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it.
If
the
problem
remains,
call
for
service.
962
A
parallel
port
configuration
error
occurred.
Action:
If
you
changed
a
hardware
option,
make
sure
that
the
parallel
port
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it.
If
the
problem
remains,
call
for
service.
1162
The
serial
port
configuration
conflicts
with
another
device
in
the
system.
Action:
Take
the
following
steps
to
correct
the
problem:
1.
Make
sure
the
IRQ
and
I/O
port
assignments
needed
by
the
serial
port
are
available.
2.
If
all
interrupts
are
being
used
by
adapters,
you
might
need
to
remove
an
adapter
to
make
an
interrupt
available
to
the
serial
port,
or
force
other
adapters
to
share
an
interrupt.
1762
Hard
disk
configuration
error.
Action:
Take
the
following
steps
to
correct
the
problem:
1.
Make
sure
that
the
hard
disk
drive
is
set
correctly
in
the
Configuration/Setup
Utility
program.
2.
Make
sure
that
the
hard
disk
drive
cables
are
correctly
and
securely
connected.
3.
If
the
problem
remains,
replace
the
hard
disk
drive.
If
the
problem
remains,
call
for
service.
Chapter
5.
Solving
problems
83
Содержание IntelliStation M Pro 6230
Страница 1: ...IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 2: ......
Страница 3: ...IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 8: ...vi IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 17: ...23 50 110 50 110 23 50 50 Safety xv ...
Страница 18: ... 23 50 50 23 50 110 50 110 50 Kg 50 23 xvi IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 19: ...23 50 110 50 110 23 50 110 50 110 23 50 50 Safety xvii ...
Страница 20: ...23 50 110 50 110 23 50 110 50 110 23 50 50 110 xviii IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 21: ...23 50 110 50 110 23 50 110 50 110 Instrução 23 Safety xix ...
Страница 44: ...22 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 98: ...76 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 130: ...108 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 150: ...128 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 158: ...136 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 164: ...142 IBM IntelliStation M Pro Types 6220 and 6230 User s Guide ...
Страница 165: ......
Страница 166: ... Part Number 88P9105 Printed in USA 1P P N 88P9105 ...