FFFF
or
other
code
not
listed
1.
Place
download
jumpers
on
the
controller
and
try
to
update
(flash)
the
firmware
code
on
the
adapter.
2.
Isolate
between
the
SCSI
subsystem
and
the
controller
by
disconnecting
all
SCSI
cables
from
the
suspected
adapter,
and
restart
the
computer.
Attention:
Do
not
press
F5.
Doing
so
changes
the
computer
configuration.
If
the
ISPR
code
is
EF10
after
the
cables
are
disconnected,
complete
the
following
steps
until
the
error
is
corrected:
a.
Identify
which
channel
is
causing
the
error
by
reconnecting
cables
one
at
a
time
and
restarting
the
computer
until
the
error
occurs
again.
b.
Check
the
termination
of
the
identified
channel
in
step
c.
Disconnect
one
drive
at
a
time
from
the
channel
identified
in
step
and
restart
the
computer
each
time
to
determine
which
drive
is
causing
the
problem.
d.
Reconnect
the
SCSI
cable
to
the
channel
identified
in
step
e.
Reconnect
the
backplane
to
the
channel
identified
in
step
3.
If
original
ISPR
code
remains
after
all
SCSI
cables
are
disconnected
and
the
computer
is
restarted,
complete
the
following
steps
until
the
error
is
corrected:
v
Reseat
the
controller.
v
Replace
the
controller.
ServeRAID
error
codes
In
the
following
error
codes,
x
can
be
any
number
or
letter.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
(Trained
service
technician
only),
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1xxx
A
microcode
checksum
error
occurred.
1.
Reseat
the
ServeRAID
controller.
2.
Replace
the
ServeRAID
controller.
2xxx
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
3000-31xx
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
3200
A
code
DRAM
error
occurred.
1.
Install
the
download
jumpers,
flash
the
latest
level
of
BIOS
code
and
firmware
for
the
controller.
Then,
remove
the
jumpers.
2.
Reseat
the
ServeRAID
controller.
3.
Replace
the
ServeRAID
controller.
Chapter
2.
Diagnostics
61
Содержание IntelliStation A Pro 6217
Страница 1: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 8: ...vi IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 16: ...xiv IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 94: ...78 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 158: ...142 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 170: ...154 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 186: ...170 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Страница 187: ......
Страница 188: ...Part Number 31R1994 Printed in USA 1P P N 31R1994...