background image

IBM Flex System Storage Expansion Node

8

Physical specifications

Dimensions and weight (approximate):

Height: 56 mm (2.2 in.)

Depth: 504 mm  (19.8 in.)

Width: 229 mm (9.2 in.)

Maximum weight: 5.9 kg (13 lb)

Shipping dimensions and weight (approximate):

Height: 240 mm (9.5 in.)

Depth: 680 mm (26.8 in.)

Width: 601 mm (23.7 in.)

Weight: 9.5 kg (21 lb)

Operating environment

When the unit is powered on, it is supported in the following environment:

Temperature: 5° C to 40° C (41° F to 104° F) 

Humidity, noncondensing: -12° C dew point (10° F) and 8% - 85% relative humidity

Maximum dew point: 24° C (75° F)

Maximum altitude: 3048 m (10,000 ft)

Maximum rate of temperature change: 5° C/hr (41° F/hr) 

Regulatory compliance

The unit conforms to the following standards:

ASHRAE Class A3  

FCC - Verified to comply with Part 15 of the FCC Rules Class A

Canada ICES-004, issue 3 Class A

UL/IEC 60950-1

CSA C22.2 No. 60950-1

NOM-019

Argentina IEC 60950-1

Japan VCCI, Class A

IEC 60950-1 (CB Certificate and CB Test Report)

China CCC (GB4943); (GB9254, Class A); (GB17625.1)

Taiwan BSMI CNS13438, Class A; CNS14336

Australia/New Zealand AS/NZS CISPR 22, Class A

Korea KN22, Class A, KN24

Russia/GOST ME01, IEC 60950-1, GOST R 51318.22, GOST R

51318.249, GOST R 51317.3.2, GOST R 51317.3.3

IEC 60950-1 (CB Certificate and CB Test Report)

CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2,

EN61000-3-3)

CISPR 22, Class A

TUV-GS (EN60950-1/IEC 60950-1, EK1-ITB2000)

Содержание Flex System 68Y8588

Страница 1: ...S infrastructure video survellance and streaming solutions Figure 1 shows the IBM Flex System Storage Expansion Node attached to an IBM Flex System x240 Compute Node Figure 1 IBM Flex System Storage E...

Страница 2: ...both processors be installed in the x220 and x240 Features The System Expansion Node has the following features Connects directly to supported compute nodes via a PCIe 3 0 interface to the compute no...

Страница 3: ...re of the Storage Expansion Node when connected to a compute node Figure 2 Architecture of the Storage Expansion Node The Expansion Node connects to a standard width compute node using the interposer...

Страница 4: ...n Node with drive tray part way extended The following table lists the hard disk drives HDDs and solid state drives SSDs supported within the Storage Expansion Node Both SSDs and HDDs can be installed...

Страница 5: ...IBM Flex System 1 90Y4412 A2Y2 ServeRAID M5100 Series Performance Accelerator for IBM Flex System 1 The cache upgrades are mutually exclusive FoD upgrades for ServeRAID are system wide If you have th...

Страница 6: ...DD arrays with only an incremental investment in solid state drive SSD technology The feature enables the SSDs to be configured as a dedicated cache to help maximize the I O performance for transactio...

Страница 7: ...hreshold Close door immediately to avoid drive damage In addition to the lights described in the previous table there are LEDs locally on each of the drive trays These lights can be observed when the...

Страница 8: ...ft Maximum rate of temperature change 5 C hr 41 F hr Regulatory compliance The unit conforms to the following standards ASHRAE Class A3 FCC Verified to comply with Part 15 of the FCC Rules Class A Can...

Страница 9: ...bm com infocenter flexsys information index jsp IBM ServerProven hardware compatibility page for IBM Flex System http www ibm com systems info x86servers serverproven compat us IBM Flex System x240 Co...

Страница 10: ...f the materials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any...

Страница 11: ...arks of International Business Machines Corporation in the United States other countries or both These and other IBM trademarked terms are marked on their first occurrence in this information with the...

Отзывы: