b) On the console, enter
cfgmgr
to configure the adapter.
c) Continue with step “18” on page 21.
13. If you are using the IBM i operating system, return to the Hardware Resource Concurrent
Maintenance display and select Power on domain.
The message
Power on complete
is shown.
14. Did you replace a PCIe3 x8 non-volatile memory SSD NVMe adapter?
• Yes: Continue with step “15” on page 21.
• No: Continue with step “18” on page 21.
15. If you installed a PCIe3 x8 non-volatile memory SSD NVMe adapter and the logical partition that
controls the adapter is running the IBM i operating system, complete the following steps to prepare
the NVMe adapter for operation:
a) Start the IBM i System Service Tools (STRSST), and specify the user name and password.
b) On the System Service Tools (SST) display, select Work with disk units > Work with disk
configuration > Work with NVM Devices > Delete existing NVM Namespaces.
c) Select the NVMe device that you installed.
d) Choose from the following options:
• If no namespaces are listed, press F12 to return to the SST main menu and continue with the
next step.
• If there are namespaces listed, complete the following steps:
1) Select 4=Delete Namespace for each of the listed namespaces.
2) Press F10 to confirm the deletion of the namespaces.
3) Press F12 to return to the SST main menu.
e) On the System Service Tools (SST) display, select Work with disk units > Work with disk
configuration > Work with NVM Devices > Create NVM Namespaces.
f) Select the NVMe device that you installed.
g) On the Create NVM Namespaces display, select the quantity and capacity of the namespaces
(disk units) that you want to create on the newly installed NVMe device.
h) Press F10 to confirm the creation of the namespaces.
i) Press F12 to return to the SST main menu.
16. Continue with step “18” on page 21.
17. If you are using the Linux operating system, complete the following steps:
a) In the Linux session on the console, press Enter after you install or replace the adapter to put the
slot into the action state.
b) Enter the slot information with the
lsslot
command, as shown in the following example.
For example, if the slot in which you installed the PCIe adapter was U7879.001.DQD014E-P1-C3.
Enter
lsslot -c pci -s U7879.001.DQD014E-P1-C3
The following screen is an example of the information that is displayed by this command:
# Slot Description Device(s)
U7879.001.DQD014E-P1-C3 PCI-X capable, 64 bit, 133MHz slot 0001:40:01.0
18. Verify the installed part.
• If you replaced the part because of a service action, verify the installed part. For instructions, see
https://www.ibm.com/support/knowledgecenter/POWER9/p9ect/
pxect_verifyrepair.htm (www.ibm.com/support/knowledgecenter/POWER9/p9ect/
pxect_verifyrepair.htm).
Installing PCIe adapters in the 9080-M9S system 21