76
Updated
28/02/01
To access IBM information specific to your country via the World Wide Web, use address: http://www.ibm.com/pc
Netfinity 7600 Internal Hard Disk Drive (HDD) and External Storage Configurator
Total Int.
Storage
1
7200 RPM Ultra160 SCSI HDDs
10,000 RPM Ultra160 SCSI HDDs
15,000 RPM Ultra160 SCSI
HDDs
9.1 GB
(P/N 37L7201)
2
18.2 GB
(P/N 37L7202)
2
36.4 GB
(P/N 37L7203)
2
9.1 GB
(P/N 37L7204)
2
18.2 GB
(P/N 37L7205)
2
36.4 GB
(P/N 37L7206)
2
9.1 GB
(P/N 19K0655)
2
18.2 GB
(P/N 19K0656)
2
0 GB
0GB Standard on Base Models
0GB Standard on Base Models
0GB Standard on Base Models
9.1 GB
1
-
-
1
-
-
1
-
18.2 GB
2 or
1
-
2 or
1
-
2 or
1
27.3 GB
3
-
-
3
-
-
3
-
36.4 GB
4 or
2 or
1
4 or
2 or
1
4 or
2
45.5 GB
5
-
-
5
-
-
5
-
54.6 GB
6 or
3
-
6 or
3
-
6 or
3
63.7GB
7
-
-
7
-
-
7
-
72.8 GB
8 or
4 or
2
8 or
4 or
2
8 or
4
81.9GB
9
-
-
9
-
-
9
-
91 GB
10 or
5
-
10 or
5
-
10 or
5
109.2 GB
-
6 or
3
-
6 or
3
-
6
127.4GB
-
7
-
-
7
-
-
7
145.6GB
-
8 or
4
-
8 or
4
-
8
163.8GB
-
9
-
-
9
-
-
9
182GB
-
10 or
5
-
10 or
5
-
10
218.4GB
-
-
6
-
-
6
-
-
254.8GB -
-
7
-
-
7
-
-
291.2 GB
-
-
8
-
-
8
-
-
327.6 GB
-
-
9
-
-
9
-
-
364 GB
(max)
-
-
10
-
-
10
-
-
This table does not represent all possible hard disk drive (HDD) configurations.
1. Select a total storage row then select the quantity of HDDs from a column corresponding to the HDD of choice. Total Internal Storage listed is 0.2
GB unless otherwise noted.
2. Netfinity 7600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.
Bay
Form
Factor
Height
Front
Access
Usage
Part
Number
Description
RPM
Height
Bays
Supported
Max.
Qty.
-
89 mm
(3.5”)
SL
Yes
Diskette
Ultra160 Hard Disk Drives (HDD)
1
-
133 mm
(5.25”)
HH
Yes
IDE CD-
ROM
37L7201
9.1 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
See diagram
10
RM 1
133 mm
(5.25”)
HH
1
Yes
Open
37L7202
18.2 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
See diagram
10
RM 2
133 mm
(5.25”)
HH
1
Yes
Open
37L7203
36.4 GB Ultra160 SCSI Hot-Swap HDD
7200
SL
See diagram
10
1...10
or
1...7
HS
SL or HH
2
Yes
Open
37L7204
9.1 GB 10K-4 Ultra160 SCSI Hot-Swap HDD
10,000
SL
See diagram
10
NB3
3
19” Rack
3U
Yes
Open
37L7205
18.2 GB 10K-4 Ultra160 SCSI Hot-Swap HDD
10,000
SL
See diagram
10
37L7206
36.4 GB 10K-4 Ultra160 SCSI Hot-Swap HDD
10,000
SL
See diagram
10
19K0655
9.1 GB 15K-rpm Ultra160 SCSI Hot-Swap
HDD
15,000
SL
See diagram
10
19K0656
18.2 GB 15K-rpm Ultra160 SCSI Hot-Swap
HDD
15,000
SL
See diagram
10
1. Two half-high (HH) bays can be combined to support a single full-high
(FH) device
2. The top bay is HH; all others are configured in groups of 3 SL bays. When a
HH drive is installed in one of these groups, only another HH or a single SL
drive can be installed in the same group. For clarity, the SCSI IDs are
identified.
3. Tower configured systems (Netfinity 8Ux24D Rack-to-Tower Kit, P/N
37L6860 is required and includes a single NetBAY3) support installation of up
to three NetBAY3s. See IBM Netfinity NetBAY3 Stackable Enclosure section
for supported devices.
Содержание eServer xSeries
Страница 20: ...19 Updated 28 02 01...
Страница 28: ...27 Updated 28 02 01...
Страница 36: ...35 Updated 28 02 01...
Страница 44: ...43 Updated 28 02 01...
Страница 58: ...57 Updated 28 02 01...
Страница 66: ...65 Updated 28 02 01...
Страница 92: ...91 Updated 28 02 01...
Страница 96: ...95 Updated 28 02 01...
Страница 116: ...115 Updated 28 02 01...
Страница 120: ...119 Updated 28 02 01...